"Military-grade" is a claim, not a test report. A sealed nickel-metal-hydride (NiMH) pack for unmanned-aircraft ground support is qualified by a chain of evidence: cell performance to IEC 61951-2, pack safety to IEC 62133-1, ingress to IEC 60529, environmental robustness to a tailored MIL-STD-810H sequence, electromagnetic compatibility to MIL-STD-461G where the platform requires it, and a transport route that is correctly described for air, sea and road. This paper sets out that chain, the tests that actually matter for a ground-support pack, the sample sizes and sequences that make the results defensible, and the documentation a customer should receive with the first article.
| Level | What is being proved | Governing documents | Evidence produced |
|---|---|---|---|
| Cell | Capacity, cycle life, charge retention, electrical performance | IEC 61951-2; supplier data sheet | Cell test report, batch certificate, cycle-life data |
| Pack | Safety under intended use and foreseeable misuse | IEC 62133-1 | Type-test report with sample traceability |
| Enclosure | Dust and water ingress | IEC 60529 | IP test report at the declared rating |
| Platform | Vibration, shock, temperature, altitude, humidity, EMC | MIL-STD-810H; MIL-STD-461G; customer tailoured profile | Environmental and EMC test reports |
| Logistics | Safe transport by air, sea and road | IATA DGR Special Provision A199; IMDG UN 3496; ADR | Air waybill statement, IMDG declaration where applicable, packing checklist |
The chain is cumulative. A pack that passes IEC 62133-1 but fails IP65 at the connector is not an IP65 pack. A pack that passes vibration but loses capacity at −20 °C is not a cold-weather pack. The qualification plan should map each customer requirement to one test and one report line, so that no requirement is left as an assumption.
IEC 61951-2 covers sealed NiMH cells for portable applications. It is a performance standard: it defines how capacity, high- and low-temperature discharge, charge retention and cycle life are measured, and the conditions under which the numbers are comparable. The table below is a practical qualification checklist, not a clause-by-clause reproduction.
| Test area | What is measured | Typical condition | Why it matters to a UAV ground pack |
|---|---|---|---|
| Rated capacity | Discharge capacity at a defined rate | 0.2C to 1.0 V/cell at 20 ± 5 °C | Baseline for the sizing calculation |
| High-temperature discharge | Capacity at elevated ambient | +45 to +60 °C | Flight-line cart in summer; charge temperature limits |
| Low-temperature discharge | Capacity and voltage at cold | −18 to −20 °C | Winter operations; brown-out risk during pulses |
| Charge retention | Self-discharge over storage | 28 days at 20 °C, or customer-defined | Pack stored in a vehicle between missions |
| Cycle life | Capacity at defined cycles | 0.2C/0.2C to 80 % of rated | Two-to-three-year service target |
| Charge acceptance | Ability to accept charge after storage | Defined charge profile | Opportunity charging from a generator |
| Overcharge endurance | Cell behaviour under continuous low-rate charge | 0.1C, 14–16 h | Trickle-charged standby packs |
The test report should state the cell model, the manufacturer, the date of manufacture, the formation/aging history and the test temperature. A capacity number without those conditions is not comparable to another supplier's number.
IEC 62133-1:2017 (nickel systems) defines safety tests under intended use and reasonably foreseeable misuse. The second edition, IEC 62133-1:2026, keeps the same test families and updates definitions and conditions. The sample sizes in the 2017 edition are shown because they are the ones most test houses still quote.
| Clause | Test | Sample size (cell / battery) | Acceptance criterion |
|---|---|---|---|
| 7.2.1 | Continuous low-rate charging | Cells | No leakage, no fire, no explosion; defined capacity retention |
| 7.2.2 | Vibration | Cells / batteries | No leakage, no fire, no explosion; voltage and mechanical integrity |
| 7.2.3 | Case stress at high ambient temperature | Batteries | No deformation that compromises safety |
| 7.2.4 | Temperature cycling | Cells / batteries | No leakage, no fire, no explosion |
| 7.3.1 | Incorrect installation | 5 sets of 4 cells | No fire, no explosion |
| 7.3.2 | External short circuit | 5 per temperature | No fire, no explosion |
| 7.3.3 | Free fall | 3 | No fire, no explosion |
| 7.3.4 | Mechanical shock | 5 | No fire, no explosion |
| 7.3.5 | Thermal abuse | 5 cells | No fire, no explosion at 130 °C oven |
| 7.3.6 | Crush | 5 cells (10 prismatic) | No fire, no explosion at 13 kN |
| 7.3.7 | Low pressure | 3 cells | No leakage, no fire, no explosion |
| 7.3.8 | Overcharge | 5 | No fire, no explosion |
| 7.3.9 | Forced discharge | 5 cells | No fire, no explosion under polarity reversal |
A pack-level test report should identify which tests were performed on cells and which on finished packs, and should include the pack's protection settings. A common gap is testing cells alone and claiming pack safety; the pack adds connectors, wiring, an enclosure and a thermistor, each of which can change the outcome of a short-circuit or crush test.

| Rating | Dust | Water | Typical UAV ground-support use | Test note |
|---|---|---|---|---|
| IP54 | Protected against dust in harmful quantities | Protected against splashing water from any direction | Sheltered test bench, vehicle cab | Enclosure and connector both assessed |
| IP55 | Dust-protected | Protected against water jets | Flight-line cart under a canopy | Jets from a 6.3 mm nozzle |
| IP65 | Dust-tight | Protected against water jets | Exposed ground cart, launch trailer | Dust-tight requires no ingress of dust |
| IP67 | Dust-tight | Protected against temporary immersion | Recovery equipment near water, open deck | Immersion at defined depth and time |
Ingress ratings are not cumulative: IP67 does not automatically mean IP65, and an IP65 connector on an IP54 enclosure gives an IP54 system. The test should be performed on the complete pack, with the connector mated and the vent in place, because that is the configuration the customer will use.
MIL-STD-810H is a method standard, not a pass/fail specification. The customer must define the tailoured test profile: temperature extremes, dwell times, vibration spectrum, shock pulses and altitude. The table below lists the methods most often relevant to a UAV ground-support pack.
| Method | Title | Typical tailoring for a ground-support pack | What it reveals |
|---|---|---|---|
| 500.6 | Low pressure (altitude) | Up to 18,000 ft / about 50 kPa, if air-shipped or stored at altitude | Enclosure pressure, venting, connector integrity |
| 501.7 | High temperature | +55 °C ambient, solar load if exposed | Charge inhibit, capacity, enclosure deformation |
| 502.7 | Low temperature | −20 to −30 °C, with operational and storage checks | Capacity, voltage sag, charger behaviour |
| 503.7 | Temperature shock | −20 to +55 °C, rapid transfer | Condensation, seals, solder joints |
| 507.6 | Humidity | 95 % RH, cycling | Corrosion, insulation resistance |
| 509.7 | Salt fog | Coastal or marine exposure | Connector and enclosure corrosion |
| 510.7 | Sand and dust | Blowing dust, if the cart is exposed | Ingress, fan and connector fouling |
| 514.8 | Vibration | Vehicle transport profile, 3 axes | Cell movement, tab fatigue, fastener loosening |
| 516.8 | Shock | Handling drop and transport shock | Enclosure cracking, cell displacement |
Two sequencing rules make the result more useful. First, run the environmental sequence on the same units that will be opened and inspected, so that internal damage is visible. Second, perform a functional check after each method, not only at the end: a pack that passes the final check may have failed intermittently after vibration and recovered by the time it was measured.
| Test | Category | What it checks | Relevance to a NiMH ground pack |
|---|---|---|---|
| CE102 | Conducted emissions, power leads | Noise fed back onto the power bus | Charger and DC-DC ripple; sensitive to layout |
| CS101 | Conducted susceptibility, power leads | Immunity to ripple and transients on the bus | Generator and winch transients |
| CS114 | Conducted susceptibility, bulk cable injection | Immunity to injected RF | Cable harness near antennas |
| CS115 | Conducted susceptibility, impulse excitation | Immunity to fast transients | Relay and contactor switching |
| CS116 | Conducted susceptibility, damped sinusoidal transients | Immunity to ringing transients | Long cables and ground loops |
| RE102 | Radiated emissions | Unintended radio emissions | Charger switching harmonics |
| RS103 | Radiated susceptibility | Immunity to incident RF fields | Operation near datalink and radar |
Not every ground cart needs the full MIL-STD-461G set. A pack that sits in a test cell can often be qualified to commercial emissions and immunity standards; a pack that operates beside a tactical radio or a radar should be tested to the platform's tailoured list. The requirement should name the tests, not just the standard.
| Document | Applies to | Does it apply to a NiMH ground pack? | Why it still matters |
|---|---|---|---|
| ASTM F3005-22 | Batteries for small unmanned aircraft systems (sUAS) | Not as a flight approval; useful as a design and documentation checklist | Defines cell, mechanical, electrical and maintenance requirements; subordinate to ASTM F2910 |
| RTCA DO-311A | Rechargeable lithium battery systems on aircraft | No; lithium-specific | Shows the level of analysis a flight pack receives |
| RTCA DO-160G | Airborne equipment environmental qualification | No, unless the pack is installed in the aircraft | Defines the airborne environmental envelope |
| MIL-PRF-32052 | Military battery, 6T format | Only if the customer specifies that form factor | Connector, case and performance requirements for legacy equipment |
| IEC 62133-1 | Portable sealed nickel cells and batteries | Yes, for pack safety | Safety baseline for ground and training packs |
The boundary is important commercially as well as technically. A supplier that implies a NiMH ground pack is "flight-certified" creates a liability it cannot support. The correct statement is that the pack is qualified for ground support to the named standards and is not a replacement for the aircraft's approved flight battery.
| Stage | Samples | Tests | Purpose |
|---|---|---|---|
| Cell screening | 10–20 cells from the production lot | Capacity, internal resistance, self-discharge | Confirm lot consistency before pack build |
| Design verification | 3–5 packs | IEC 62133-1 safety tests; IP rating | Prove the design and protection settings |
| Environmental | 3 packs | MIL-STD-810H tailored sequence | Prove transport and field robustness |
| EMC | 1–2 packs plus charger | MIL-STD-461G tailored list | Prove compatibility with the platform |
| Endurance | 5–10 packs | Cycle life to 80 % capacity | Prove the service-life claim |
| First article | 1 production pack | Dimensional, functional, charge/discharge, label | Confirm production conformity |
The sequence should put non-destructive tests first (capacity, IP, functional), then environmental, then destructive safety tests, and finally endurance on separate samples. Testing a pack to crush and then using it for cycle life is not a valid plan; the sample populations must be independent.
| Failure | Likely cause | Design response | Test that catches it |
|---|---|---|---|
| Voltage sag during launch pulse | High internal resistance, small cells, long wiring | Larger cells, shorter harness, capacitor buffer | Pulse discharge at low temperature |
| Capacity loss after cold soak | Electrolyte conductivity, cell mismatch | Cell selection, heater or thermal insulation | IEC 61951-2 low-temperature discharge |
| Connector corrosion | Salt fog, condensation, dissimilar metals | Plated contacts, sealed connector, vent | MIL-STD-810H 509.7 and 507.6 |
| Enclosure cracking | Drop, shock, brittle resin | Ductile material, ribs, crush space | IEC 62133-1 free fall; MIL-STD-810H 516.8 |
| Overcharge heating | Charger misses termination; no thermistor | −ΔV plus dT/dt plus timer plus temperature cut-off | IEC 62133-1 overcharge; charge-fault injection |
| Cell reversal | Deep discharge, mismatched cells | Low-voltage cutoff at 1.0 V/cell; matched cells | IEC 62133-1 forced discharge |
| Radiated emissions failure | Switching charger, poor filtering | Input filter, shielding, layout | MIL-STD-461G CE102 and RE102 |
| Document | Content | Why it matters |
|---|---|---|
| Cell test report | Model, lot, capacity, cycle life, temperature performance | Traceability and baseline for pack claims |
| Pack type-test report | IEC 62133-1 tests, sample IDs, results, protection settings | Evidence of safety qualification |
| IP test report | Rating, test setup, connector configuration, result | Defines what "waterproof" means |
| Environmental report | MIL-STD-810H methods, tailoring, functional checks | Defines the operating envelope |
| EMC report | MIL-STD-461G tests, limits, setup photos | Platform compatibility evidence |
| Transport statement | UN 3496 / A199 wording, state of charge, packing checklist | Correct papers for air, sea or road |
| Instructions and SDS | Charge, storage, disposal, safety data sheet | Legal and operational requirement |
| Requirement | Test | Sample | Acceptance |
|---|---|---|---|
| Capacity ≥ 20 Ah at 0.2C, 25 °C | IEC 61951-2 rated capacity | 5 packs | ≥ 20 Ah |
| Usable energy ≥ 250 Wh at −10 °C | Low-temperature discharge | 3 packs | ≥ 250 Wh delivered |
| No fire or explosion under misuse | IEC 62133-1 test set | Per clause sample sizes | No fire, no explosion |
| IP54 with mated connector | IEC 60529 | 3 packs | No harmful ingress |
| Transport vibration and drop | MIL-STD-810H 514.8 / 516.8 | 3 packs | No loss of function, no cell displacement |
| Charge/discharge at −20 to +55 °C | MIL-STD-810H 501.7 / 502.7 | 3 packs | Functional within derated limits |
| Conducted and radiated emissions | MIL-STD-461G CE102 / RE102 | 1 pack plus charger | Below contractual limits |
| 500 cycles to 80 % capacity | Cycle-life test | 5 packs | ≥ 80 % of rated at 500 cycles |
This matrix is deliberately written as requirements with numbers, not as a list of standards. A test plan that says "qualified to MIL-STD-810H" without a temperature, a duration and an acceptance criterion is not auditable, and it will not survive a customer's quality review.
| Mode | Classification | Key condition | Documentation |
|---|---|---|---|
| Air (IATA DGR) | Not Restricted under Special Provision A199 | Short circuit prevented; unintentional activation prevented | Air waybill wording with "Not Restricted" and A199, where an AWB is used |
| Sea (IMDG) | UN 3496, Class 9, special provisions 117 and 963 | Packing instruction SP963; terminals protected | IMDG declaration where required |
| Road (ADR) | Not applicable | Short circuit and activation prevented as good practice | No ADR declaration |
| Storage | Not a transport regime | 30–50 % state of charge; dry, ventilated, away from heat | Internal procedure and SDS |
The air case is the one most often mis-documented. UN 3496 is not used as an air waybill description for NiMH; the correct statement is "Not Restricted" with Special Provision A199, provided the batteries are protected against short circuit and unintentional activation. A shipper who writes "UN 3496" on an air waybill has copied a sea or road entry into the wrong regime.

It is the most widely accepted safety baseline for portable sealed nickel cells and batteries. A military customer may also require MIL-STD-810H and MIL-STD-461G, but IEC 62133-1 remains the evidence that the pack is safe under intended use and foreseeable misuse.
No. It defines performance tests — capacity, temperature behaviour, charge retention and cycle life. Safety is addressed by IEC 62133-1. A complete qualification uses both.
No. The rating applies to the complete enclosure, including the connector, the vent and the cable entry. A sealed box with an open connector is not IP67, and a test performed with the connector blanked off does not represent the installed configuration.
No. It provides methods and guidance; the customer must tailor the temperatures, durations, vibration spectrum and shock pulses to the application. The test report should state the tailoring, not just the method number.
UN 38.3 is the lithium-battery transport test regime. Nickel-metal-hydride batteries do not require a UN 38.3 test summary. By sea they are UN 3496, Class 9; by air they are Not Restricted under IATA Special Provision A199 when short-circuit and unintentional activation are prevented.
For a mature cell and a defined pack, plan 10–16 weeks: 2–3 weeks for cell screening and pack build, 3–4 weeks for IEC 62133-1, 3–4 weeks for environmental and EMC, and 4–6 weeks for cycle life. Custom tooling, new cells or a first-of-type enclosure can double the schedule.
IEC 61951-2:2017+AMD1:2022, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride; IEC 62133-1:2017 and IEC 62133-1:2026, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications — Part 1: Nickel systems (test list and sample sizes from the 2017 edition, Table 1); IEC 60529:1989+AMD1:2013+AMD2:2013, Degrees of protection provided by enclosures (IP Code); IATA Dangerous Goods Regulations, Special Provision A199 and the IATA guidance document for UN 3496 nickel-metal-hydride batteries (air transport: Not Restricted; sea: UN 3496 Class 9, special provisions 117 and 963); UNECE ADR and IMDG references for UN 3496; MIL-STD-810H, Methods 500.6, 501.7, 502.7, 503.7, 507.6, 509.7, 510.7, 514.8 and 516.8; MIL-STD-461G, CE102, CS101, CS114, CS115, CS116, RE102 and RS103; ASTM F3005-22 and ASTM F2910; RTCA DO-311A and DO-160G; MIL-PRF-32052. Test durations and sample counts are planning guidance, not a substitute for the customer's qualification plan.
This closes the C13 set on military UAV power. The series continues with the next D7 platform; the three-paper structure — working conditions and principles, selection and design, testing and certification — remains the same.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.