NiMH Battery Packs for Non-Implantable Medical Devices

NiMH battery packs for non-implantable medical devices — at a glance

Weijiang Power is an OEM/ODM manufacturer of nickel-metal hydride (NiMH) cells and assembled battery packs for non-implantable medical devices, medical carts, diagnostic equipment and backup systems. We build packs to the device maker's voltage, capacity, dimensions, connector and charging profile, and supply the cell and pack documentation needed for the device's own qualification process.

Supplier type NiMH cell and pack manufacturer. Legal entity: Shenzhen Weijiang Battery Co., Ltd.; factory: Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong, China.
Pack voltage 2.4 V to 26.4 V and above, series/parallel configurations; 1.2 V nominal per NiMH cell.
Cell sizes AA, AAA, A, Sub-C, C and D; specialty 2/3A and 4/5A sizes on request.
Capacity Selected by cell size and duty cycle. AA typically 600–2,700 mAh, Sub-C up to about 4,200 mAh, D up to about 10,000 mAh; exact rating is confirmed against the device's discharge profile.
Protection PCM/BMS for over-charge, over-discharge, over-current and short-circuit protection; optional NTC thermistor and charge/discharge FET configuration.
Terminals and connectors Welded nickel tabs, wire leads, JST, Molex, XT60 or custom connectors; lead length and pinout per drawing.
Housing and labeling Heat-shrink sleeve, PVC/ABS or PCB-frame housing, custom labels, part numbers and packaging.
Documentation IEC 62133, IEC 61951-2, CE, RoHS, REACH and MSDS documentation as applicable; UN38.3 only for lithium packs, not NiMH.
Quality system ISO 9001:2015, IATF 16949 and ISO 14001. We are a battery pack manufacturer, not a medical device manufacturer, and do not claim ISO 13485.
MOQ and lead time Flexible MOQ confirmed per cell and pack; samples typically 7–15 days after specifications are agreed; standard pack production 7–12 days; custom pack production 15–25 days.

Where NiMH fits in medical equipment

NiMH is a practical choice for non-implantable medical devices that need a rechargeable, inherently stable battery rather than a high-energy lithium pack. Typical projects include patient monitors, infusion pumps, diagnostic carts, nurse-call backup units, fluid warmers and portable laboratory instruments. NiMH is normally used for portable or backup power; it is not proposed for implantable devices.

The chemistry is tolerant of overcharge and abuse compared with lithium-ion, and it does not require the same thermal-runaway chain reaction protection. That makes NiMH a good fit when the device has a defined charge profile, a moderate energy density requirement and a preference for a pack that is simple to service and transport.

Pack requirements medical device teams specify

A medical NiMH pack is not selected by voltage alone. The device maker's requirement package usually determines cell size, protection thresholds, connector, housing and documentation. The table below lists the inputs we need before quoting a pack.

Requirement What to send Why it matters
Electrical Nominal voltage, capacity at a defined discharge rate, continuous and peak current, operating temperature, required runtime and cycle life. Sets the series/parallel layout and the cell grade; without the discharge rate, a capacity number is not comparable.
Mechanical Maximum length, width and height, weight limit, cell orientation, lead length, connector part number and mounting method. Determines whether a standard cell arrangement fits or a custom holder/frame is needed.
Charging Existing charger voltage/current, charge termination method, temperature sensor requirement and expected recharge time. NiMH charging is sensitive to overcharge and cell matching; the PCM and NTC must match the charger.
Protection Over-charge, over-discharge, over-current and short-circuit thresholds; whether a PCM/BMS is required; NTC type and placement. Protects the pack and the device; thresholds must be agreed, not guessed.
Documentation Destination market, required standards, whether IEC 62133, CE, RoHS, REACH, MSDS or UL documents are needed, and any customer-specific test report format. Defines the document package and the tests that must be completed before shipment.
Commercial Prototype quantity, annual volume, expected production MOQ, sample date and mass-production date. Sets the tooling, cell procurement and production slot; custom packs and standard packs have different schedules.

Cell, protection and connector options

  • Cells: AA, AAA, A, Sub-C, C and D NiMH cells, plus 2/3A and 4/5A specialty sizes. Cells are matched and resistance-sorted before pack assembly.
  • Pack configuration: series strings set voltage; parallel banks add capacity. Standard pack voltages include 2.4, 3.6, 4.8, 6, 7.2, 8.4, 9.6, 10.8, 12, 13.2, 14.4, 15.6, 16.8, 18, 19.2, 20.4, 21.6, 24 and 26.4 V; custom strings on request.
  • Protection: PCM/BMS for over-charge, over-discharge, over-current and short circuit; optional NTC and charge/discharge FET configuration.
  • Terminals: welded nickel tabs, flat or button top, lead wires, JST/Molex/XT60 or a connector specified by the device maker.
  • Housing: heat-shrink sleeve, PVC/ABS housing, PCB-frame housing, custom labels and retail or bulk packaging.

Compliance and documentation: what we can supply

Item Scope Note for NiMH medical projects
IEC 62133 Secondary cell and battery safety Pack-level safety documentation can be supplied as applicable to the cell and pack configuration.
IEC 61951-2 NiMH cell performance Cells are built to IEC 61951-2 practice; performance data is matched to the requested discharge profile.
CE EU market entry CE documentation as applicable to the battery pack; the final device's CE marking remains the device maker's responsibility.
RoHS / REACH EU substance restrictions Material declarations and test reports for the supplied pack configuration.
MSDS Transport and safety data MSDS is the transport document for NiMH packs; UN38.3 is not applicable to NiMH.
UN38.3 Lithium transport testing Only for lithium cells and packs. Do not request or expect UN38.3 for a NiMH pack.
ISO 9001:2015 / IATF 16949 / ISO 14001 Quality and environmental management Factory quality system certifications; they are not medical device certifications.

Medical device responsibility. Weijiang Power manufactures the battery pack; the device maker remains responsible for the final device's risk management, validation and medical device certification, including IEC 60601-1 where applicable. We do not claim ISO 13485 or a medical device manufacturing license. This boundary is stated deliberately so procurement and quality teams can plan the correct split of responsibilities.

How we build and validate a medical battery pack

  1. Requirement review. We check voltage, capacity at the stated discharge rate, dimensions, connector, charger profile and destination market before quoting.
  2. Cell selection and matching. Cells are selected by size, capacity grade and current capability, then matched and resistance-sorted before welding.
  3. Pack design. The layout, PCM/BMS thresholds, NTC placement, leads, connector and housing are documented on a drawing for approval.
  4. Prototype and sample. A sample pack is built to the approved drawing; the customer tests it in the device and confirms the charge/discharge behavior.
  5. Production and documentation. Production follows the approved configuration; the agreed test reports and documents are issued with the shipment.

MOQ, samples and lead time

Stage Typical timing Notes
Engineering sample 7–15 days After specifications and drawing are agreed; sample quantities are quoted per project.
Standard pack production 7–12 days Repeat configurations with released materials.
Custom pack production 15–25 days New housing, connector, PCM or cell arrangement; tooling and material lead time included.
MOQ Flexible, confirmed per project Prototype and small-batch quantities can be quoted; production MOQ depends on cell size and pack configuration.

RFQ checklist for a medical NiMH pack

  • Device type and whether the pack is for portable power or backup.
  • Nominal voltage, capacity at a defined discharge rate, continuous/peak current and required runtime.
  • Maximum dimensions, weight limit, cell orientation and mounting method.
  • Connector part number, lead length, pinout and wire gauge.
  • Charger voltage/current, termination method and NTC requirement.
  • PCM/BMS thresholds and any device-specific protection requirements.
  • Destination market and required documents: IEC 62133, CE, RoHS, REACH, MSDS, UL or customer format.
  • Prototype quantity, annual volume, target sample date and production date.

Frequently asked questions

Q: Who makes NiMH battery packs for non-implantable medical devices?
A: Weijiang Power, the battery pack brand of Shenzhen Weijiang Battery Co., Ltd., makes custom NiMH packs for non-implantable medical devices in China. Typical programs include patient monitors, infusion pumps, diagnostic carts, nurse-call backup, fluid warmers and portable laboratory instruments. Send the voltage, capacity at the working discharge rate, dimensions, connector, charger profile and annual volume; we will confirm the cell, PCM/BMS and sample schedule. We are a battery pack manufacturer, not a medical device manufacturer, and do not claim ISO 13485.

Q: Is Weijiang Power a medical device manufacturer?
A: No. We are a NiMH cell and battery pack manufacturer. The device maker remains responsible for the finished device's risk management, validation and medical device certification, including IEC 60601-1 where applicable. We do not claim ISO 13485 or a medical device manufacturing license.

Q: Which certifications and documents can you supply?
A: We can supply IEC 62133 and IEC 61951-2 documentation, CE, RoHS, REACH and MSDS as applicable to the pack, plus ISO 9001:2015, IATF 16949 and ISO 14001 factory certificates. UL documentation is available where applicable. UN38.3 is only for lithium packs.

Q: Does a NiMH battery pack need UN38.3?
A: No. UN38.3 is a lithium battery transport test. NiMH packs use MSDS and the carrier's dangerous-goods rules; UN38.3 should not be requested for a NiMH pack.

Q: What is the MOQ for a medical NiMH pack?
A: MOQ is flexible and confirmed per project. Prototype and small-batch quantities can be quoted; production MOQ depends on the cell size, pack configuration and whether new tooling is required.

Q: What are the sample and production lead times?
A: Engineering samples typically take 7–15 days after specifications and drawings are agreed. Standard pack production is typically 7–12 days; custom packs with new housing, connectors, PCM or cell arrangements typically take 15–25 days.

Q: Can you use our specified connector, PCM and NTC?
A: Yes. We can use JST, Molex, XT60 or a customer-specified connector, set PCM/BMS thresholds to the agreed values, and add an NTC thermistor with the specified resistance and placement. The drawing is approved before the sample is built.

Q: Can you supply both the NiMH cells and the finished pack?
A: Yes. We manufacture NiMH cells and assemble the finished pack, so cell selection, matching, pack assembly and documentation can be handled in one project instead of split between a cell supplier and a pack assembler.

Q: Can you support EU and US market entry?
A: We can provide the battery pack documents normally requested for EU and US market entry, including IEC 62133, CE, RoHS, REACH and MSDS, plus UN38.3 only for lithium packs. The importer and device maker remain responsible for their own market-entry declarations and final device testing.

Related buyer guides