A counter-UAS system is a chain of sensors, decision logic and effectors, and every link has a different electrical personality. A passive RF sensor sips power while it listens. A radar draws a pulsed load whose peak is many times its average. An EO/IR gimbal is a steady servo and video load. A jamming amplifier can draw hundreds of watts to produce tens of watts of RF, and its thermal design matters more than its nameplate. The command-and-control laptop and datalink sit on top of all of it. This paper separates those loads, gives the arithmetic that connects RF output to DC input, and states precisely where a sealed nickel-metal-hydride (NiMH) pack is defensible around a counter-UAS system — and where it is not.
Procurement documents often describe a counter-UAS system by its effect — "it jams a drone at 2 km" — and omit the electrical architecture. That omission hides the fact that detection, C2 and mitigation can be distributed across several boxes, vehicles and sites. The table below separates the layers and their power character.
| Layer | Typical equipment | Electrical character | Dominant design constraint |
|---|---|---|---|
| Detection — radar | Short-range surveillance radar, 3D/4D radar, passive coherent location | Pulsed; high peak, low duty cycle; processor continuous | Peak current, thermal cycling, false-alarm processing |
| Detection — RF | Wideband spectrum monitor, protocol classifier, direction finder | Continuous receiver; short processing bursts | Receiver noise floor, compute load, antenna front end |
| Detection — EO/IR | Zoom gimbal, cooled or uncooled thermal camera, laser rangefinder | Continuous servo and video; periodic cooler or heater | Stabilisation power, video processing, window heater |
| Detection — acoustic | Microphone array, acoustic classifier | Continuous low-power sampling; edge compute | Wind noise, array spacing, always-on budget |
| C2 and datalink | Rugged laptop, tablet, radio, network switch, recorder | Continuous, moderate power; radio bursts | Display and compute, link security, latency |
| Mitigation — RF | Barrage jammer, spot jammer, sweep jammer, GNSS disruptor | High-power bursts; duty cycle from seconds to continuous | Amplifier efficiency, thermal path, spectral compliance |
| Mitigation — kinetic or directed energy | Net gun, interceptor, high-power microwave, laser | Very high peak, very short duration, or continuous beam | Pulse energy, capacitor bank, platform integration |
The table is deliberately generic. A radar that is "10 W average" may draw a 500 W peak for a few microseconds; a jammer that is "100 W RF" may draw 350 W DC for minutes. A battery specification that lists only one number is incomplete.
Detection is the part of a counter-UAS system that must run continuously, often for hours before a target appears. Its average power therefore sets the battery, while its peak power sets the DC-DC converter and the connector.
| Sensor | Typical average power | Typical peak or burst | Duty character | Note |
|---|---|---|---|---|
| Short-range surveillance radar | 20–80 W | 100–500 W pulse | Scan plus processing | Values are illustrative; solid-state radars vary widely |
| Passive RF spectrum monitor | 5–25 W | 10–40 W during FFT bursts | Continuous receive | Lower if edge processing is duty-cycled |
| EO/IR gimbal with zoom | 10–40 W | 60–120 W during heater or zoom | Continuous | Window heater and cooler are the peaks |
| Acoustic array and classifier | 2–10 W | 10–20 W during classification | Continuous sampling | Wind and site noise drive false positives |
| Edge AI compute | 15–60 W | 80–150 W during model inference | Bursty | GPU or NPU peaks are short but repeated |
The radar is the hardest load to specify because its average and peak differ by an order of magnitude. A solid-state X-band radar may transmit a few hundred watts peak with a duty cycle below 5 %, while its signal processor runs continuously. The battery sees the average; the DC-DC converter and capacitor bank see the pulse. If the converter cannot supply the pulse, the rail collapses and the processor reboots — a failure that looks like a software bug.
Passive RF detection is the opposite case: low average power, but a wideband receiver and a fast Fourier transform engine that may run continuously. The power budget is dominated by the compute and the analogue front end, not by a transmitter. EO/IR adds a mechanical servo and a video pipeline; its peak occurs when a window heater or a cooler turns on, not when the image changes.
The most common error in counter-UAS power budgets is to treat the RF output rating as the electrical input. An RF power amplifier is not 100 % efficient. Class AB amplifiers commonly run 20–35 % efficiency at saturation; GaN designs can do better, but the driver, bias, filtering and cooling still consume power. The DC input is approximately:
PDC ≈ PRF / ηamp + Pdriver + Pcontrol + Pcooling
| RF output | Assumed amplifier efficiency | DC input to amplifier | With driver, control and cooling | Illustrative continuous current at 28 V |
|---|---|---|---|---|
| 10 W | 30 % | 33 W | ≈ 45–55 W | ≈ 1.6–2.0 A |
| 50 W | 30 % | 167 W | ≈ 190–220 W | ≈ 6.8–7.9 A |
| 100 W | 30 % | 333 W | ≈ 370–420 W | ≈ 13.2–15.0 A |
| 400 W | 30 % | 1,333 W | ≈ 1,450–1,650 W | ≈ 51.8–58.9 A |
| 1 kW | 35 % | 2,857 W | ≈ 3.1–3.5 kW | ≈ 111–125 A |
These are planning figures, not measured data. The point is the ratio: a man-portable jammer with 10–30 W RF may draw 50–120 W DC; a vehicle-mounted 100–400 W jammer may draw 0.4–1.7 kW; a fixed-site 1–10 kW jammer may draw 3–30 kW. The antenna gain, beamwidth and frequency band determine the effect at the target, but they do not reduce the DC input.
Duty cycle is the second decisive variable. A barrage jammer may run continuously for minutes; a spot jammer may transmit only when a target is in the beam; a sweep jammer may spend most of its time settling. A 400 W RF module that runs at 20 % duty cycle draws an average of about 290 W DC, but its peak is still 1.5 kW. The battery, alternator and converter must be sized for the peak, while the thermal system can be sized for the average if the amplifier's thermal mass is sufficient.
C2 is the continuous hotel load. A rugged laptop draws 60–150 W; a tablet 15–30 W; a network switch 10–30 W; a datalink radio 10–50 W in receive and 30–100 W in transmit. A recording and video-distribution server can add another 50–200 W. These loads are small compared with a jammer but they never stop, and they are the loads that a NiMH support pack can carry well.
| C2 item | Typical power | Duty | Why it matters |
|---|---|---|---|
| Rugged laptop or tablet | 30–150 W | Continuous | Display, compute, storage; often the largest continuous load after EO/IR |
| Datalink radio | 10–100 W | Receive continuous, transmit burst | Link margin and antenna height drive transmit power |
| Network switch and router | 10–30 W | Continuous | Distribution and redundancy; easy to forget |
| Video recorder or server | 50–200 W | Continuous during operations | Evidence chain and after-action review |
| Display wall or second screen | 30–120 W | Continuous | Operations centre; not present in a man-pack |
| Platform | Typical power source | Typical mission load | Battery role | NiMH relevance |
|---|---|---|---|---|
| Man-portable detector or jammer | Li-ion backpack or belt pack, 14.4–28.8 V | 20–150 W | Primary energy; hot-swappable | Training and test packs; legacy equipment; not the primary tactical pack |
| Vehicle-mounted system | 12/24/28 V alternator plus lead-acid or Li-ion | 0.3–2 kW | Engine-off buffer and ride-through | Ground-support and test bench; auxiliary buffer in legacy vehicles |
| Fixed site or mobile mast | Mains, UPS, generator, solar | 1–30 kW | UPS ride-through; generator start | Remote sensor nodes, charger buffers, maintenance packs |
| Shipborne | Ship's 24/48 V DC or AC bus | 1–50 kW | UPS and emergency source | Portable test sets and training equipment |
| Airborne interceptor | Li-ion or LiPo flight pack | kW-class peak | Flight energy | Not defensible for the flight pack |
A man-portable counter-UAS detector is an energy-limited device. Its battery must be light because a soldier carries it, and its energy density requirement is severe. Lithium-ion is the rational choice. A vehicle system has mass and alternator capacity, so lead-acid or lithium can carry the buffer; a fixed site has mains and a generator. NiMH does not win the primary pack in any of these, but it can win the support role because it is robust, inexpensive per cycle, tolerant of overcharge and does not carry the lithium transport classification.
The average power of a counter-UAS system is not the sum of nameplate ratings. It is the time-weighted sum of each load, including standby, receive, transmit and thermal management. The table below shows a worked example for a vehicle-mounted system with a 100 W RF jammer, a 30 W radar, a 25 W EO/IR gimbal, a 90 W C2 laptop and a 20 W datalink.
| Load | Active power | Duty cycle | Average power | Notes |
|---|---|---|---|---|
| Radar | 60 W | 100 % | 60 W | Processor continuous; pulse peak supplied by capacitor bank |
| EO/IR gimbal | 25 W | 100 % | 25 W | Heater intermittent, not included |
| C2 laptop | 90 W | 100 % | 90 W | Display brightness dependent |
| Datalink | 40 W transmit | 10 % | 4 W plus 10 W receive | Bursty |
| RF jammer | 420 W DC | 20 % | 84 W | Peak still 420 W; thermal design uses average |
| Cooling fans and heaters | 40 W | 50 % | 20 W | Ambient and enclosure dependent |
| Total average | ≈ 293 W | Illustrative; measure the actual profile |
The example shows why a 300 W average can coexist with a 1 kW peak. A 24 V 40 Ah NiMH pack stores 960 Wh; at 80 % usable depth and a 0.85 end-of-life factor it delivers about 653 Wh, which is about 2.2 h at 293 W. The same pack can supply a 1 kW pulse for a few minutes if its internal resistance and connector are sized for it. A pack sized only from the average would be half the mass but would fail on the peak.
| Application | Why NiMH fits | What to specify |
|---|---|---|
| Training counter-UAS set | Repeated charge and discharge, abuse tolerance, low cost per cycle | 24 V 20–40 Ah, 20 A continuous, 60 A pulse, IP54, UN 3496 |
| Ground-support cart | Carries C2, chargers and test equipment between generator runs | 24 V 40–100 Ah, 30 A continuous, 100 A pulse, LVD, fuse |
| Battery test bench | Bench power for detectors and jammer modules; low ripple | 12/24 V 10–30 Ah, current limit, e-stop, thermistor |
| Remote sensor node | Solar-buffered, low average load, wide temperature | 12 V 7–20 Ah, low self-discharge, −20 °C capacity data |
| Legacy man-pack | Original design may specify NiMH; drop-in replacement avoids requalification | Match voltage, connector, thermistor and charge profile |
| Ride-through buffer | Bridges generator start or mains transfer; tolerant of trickle charge | 24/48 V, 5–15 min at rated load, reverse-polarity protection |
| Charger buffer | Absorbs charger inrush and protects the DC bus | 24 V 10–20 Ah, low internal resistance, thermal management |

| Item | Published or defined value | What it tells a pack designer |
|---|---|---|
| IEC 61951-2:2017 + A1:2022 | Performance and cycle-life requirements for sealed NiMH cells | Defines capacity, high-rate discharge, charge retention and endurance tests |
| IEC 62133-1:2017 | Safety requirements for sealed NiMH cells and batteries | Defines abuse, thermal, mechanical and electrical safety tests |
| IEC 60529 | IP ingress protection | IP54 for sheltered ground carts; IP65/67 for exposed nodes |
| MIL-STD-810H | Environmental test methods | Temperature, humidity, salt fog, sand, vibration and shock |
| MIL-STD-461G | Electromagnetic interference control | CE102, RE102, CS101 and RS103 are the usual starting points |
| UN 3496 | Nickel-metal-hydride battery transport entry | Nickel chemistry, not UN 3480/3481; no UN 38.3 summary required |
| IATA A199 | Packing instruction for nickel-metal-hydride batteries | Air cargo route; confirm quantity limits per shipment |
The standards table is deliberately short. A counter-UAS support pack does not need every standard in the catalogue; it needs the ones the platform actually invokes. A ground cart may need IEC 61951-2, IEC 62133-1, IP54 and UN 3496. A remote sensor node may add MIL-STD-810H and solar charge behaviour. A vehicle buffer may add MIL-STD-461G and a transient test against the vehicle bus. Over-specification raises cost without improving safety.
| Question | Why the answer changes the pack | Typical answer to expect |
|---|---|---|
| Is the pack carried, vehicle-mounted, or fixed? | Sets mass, ingress, vibration and transport requirements | Ground support or fixed node; not carried on the mission |
| What is the continuous and peak load? | Sets cell count, connector, fuse and converter | 100–300 W continuous; 1 kW pulse for jamming |
| What is the duty cycle of the jammer? | Separates thermal design from energy design | 10–30 % for spot or sweep; continuous for barrage |
| What is the lowest and highest ambient temperature? | Sets usable capacity, charge limits and heater need | −20 to +55 °C for field; 0–40 °C for bench |
| How is the pack charged? | Sets charger, balancing and state-of-charge policy | Generator, vehicle or solar; opportunity charging |
| What ingress and shock does it see? | Sets IP rating, enclosure and mounting | IP54–IP67; vehicle transport and handling drops |
| What transport documentation is required? | Sets UN 3496 paperwork and packing | Road and air cargo; nickel chemistry, not lithium |
Write the requirement around the support mission, not the effector's nameplate. A ground cart that supports four hours of C2 and sensor operation needs an energy budget of four hours at the average load, plus a pulse margin for the jammer. A training set needs cycle life and abuse tolerance, not energy density. A remote node needs low self-discharge and a solar charge profile, not a 10 C discharge rating. A test bench needs measurement accuracy and a safe current limit, not a rugged enclosure.
The next paper turns these principles into a sizing procedure: load audit, chemistry comparison, cell count, derating stack, charge termination and protection. The third paper covers the qualification route, including the environmental, EMC and transport tests that a "military-grade" claim usually omits.

Not as the primary pack of a man-portable tactical detector or an airborne interceptor. Those are lithium-ion or lithium-polymer because mass and energy density are decisive. NiMH appears in training sets, ground-support carts, test benches, remote sensor nodes, legacy equipment and short ride-through buffers, where robustness, cost per cycle and simpler transport matter more than gravimetric energy density.
Because the amplifier is not 100 % efficient. A 100 W RF output at 30 % efficiency draws about 333 W DC, and driver, control and cooling add more. A 400 W module can draw 1.5 kW. The antenna gain changes the effect at the target, but it does not reduce the DC input.
It can supply a short pulse if the pack, connector, fuse and converter are sized for it and the voltage sag stays within the amplifier's input range. The datasheet must state the pulse current and duration, not only the continuous rating. A pack that is adequate on average may still fail on the pulse.
A detection battery is part of the mission: its failure blinds the system. A support battery powers training, test, C2 backup or ground cart loads; its failure delays a session or a sortie. That difference allows a wider chemistry choice, a simpler BMS and a different transport route.
At minimum, IEC 61951-2 for cell performance and IEC 62133-1 for safety, plus IEC 60529 for ingress and UN 3496 for transport. If the platform invokes military environmental or EMC requirements, MIL-STD-810H and MIL-STD-461G apply. The exact subset should be written into the requirement; not every pack needs every standard.
Nickel-metal-hydride batteries are assigned UN 3496, not the lithium entries UN 3480 or UN 3481, and no UN 38.3 test summary is required. The applicable packing instruction and quantity limits depend on the configuration and mode; the shipper should confirm them for each shipment.
U.S. Department of Defense, Counter-Small Unmanned Aircraft Systems Strategy (2021); U.S. Federal Aviation Administration, Counter-UAS and UAS traffic management publications; IEC 61951-2:2017 + A1:2022, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride; IEC 62133-1:2017, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications — Part 1: Nickel systems; IEC 60529, Degrees of protection provided by enclosures (IP Code); MIL-STD-810H, Environmental Engineering Considerations and Laboratory Tests; MIL-STD-461G, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment; UN Manual of Tests and Criteria, UN 3496; IATA Dangerous Goods Regulations, Packing Instruction A199; ITU Radio Regulations. Power values marked illustrative are planning figures, not measurements.
Paper B — Selecting and sizing sealed NiMH packs for counter-UAS support equipment: load audit, chemistry comparison, cell configuration, derating stack, charge termination and protection. Paper C — Testing and certifying those packs: IEC 61951-2, IEC 62133-1, IEC 60529, MIL-STD-810H, MIL-STD-461G, abuse testing and the UN 3496 route.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.