Sizing a sealed NiMH pack for counter-UAS support equipment starts with a load audit, not with a catalogue page. The pack must carry a defined mix of C2, sensor, datalink, test and charging loads for a defined time, at a defined temperature, with a defined end-of-life margin, and it must survive the largest pulse the system can produce. This paper gives a six-step procedure that turns those inputs into a cell count, a capacity, a connector and a protection scheme. Every worked example is marked illustrative; the method, not the number, is the deliverable.
List every load the pack will supply, its active power, its standby power and its duty cycle. Do not use the system's total nameplate; use the measured or specified load of each box. The table below is a template for a vehicle-mounted counter-UAS support cart.
| Load | Active power | Standby power | Duty cycle | Energy per 4 h | Notes |
|---|---|---|---|---|---|
| C2 laptop and display | 90 W | 8 W | 100 % | 360 Wh | Display brightness dependent |
| Datalink radio | 40 W transmit | 10 W receive | 10 % transmit | ≈ 50 Wh | Receive power counted separately |
| EO/IR gimbal | 25 W | 5 W | 100 % | 100 Wh | Heater intermittent |
| Radar processor | 60 W | 10 W | 100 % | 240 Wh | Pulse peak supplied by capacitor bank |
| Jammer module | 420 W DC | 0 W | 20 % | 336 Wh | Peak 420 W; thermal average lower |
| Cooling fans | 40 W | 0 W | 50 % | 80 Wh | Ambient dependent |
| Total | ≈ 1,166 Wh | Illustrative four-hour mission |
The audit produces two numbers: the energy required for the mission and the maximum simultaneous power. The energy sets the capacity; the power sets the cell count, the connector, the fuse and the DC-DC converter. A third number, the largest pulse current and its duration, sets the pack's internal resistance and voltage-sag limit.

| Property | Sealed NiMH | Li-ion (NMC/LFP) | LiFePO4 | VRLA lead-acid |
|---|---|---|---|---|
| Nominal cell voltage | 1.2 V | 3.6–3.7 V (NMC), 3.2 V (LFP) | 3.2 V | 2.0 V |
| Pack specific energy (planning) | 70–100 Wh/kg | 150–250 Wh/kg | 90–140 Wh/kg | 30–45 Wh/kg |
| Cycle life to 80 % | 500–1,000 | 500–1,500 | 2,000–5,000 | 200–500 |
| Pulse capability | 3–8 C short pulse | 5–20 C with BMS | 5–15 C | 3–8 C but large mass |
| Temperature range | −20 to +60 °C, capacity derated cold | −20 to +60 °C with BMS limits | −20 to +60 °C | −15 to +50 °C |
| Transport | UN 3496; no UN 38.3 summary | UN 3480/3481; UN 38.3 summary | UN 3480/3481; UN 38.3 summary | UN 2794 or non-regulated |
| Abuse tolerance | High; tolerant of overcharge and over-discharge | Moderate; BMS required | High; BMS required | Moderate; ventilation required |
| Cost per cycle | Low to moderate | Moderate | Moderate to high | Low but heavy |
The comparison is not a ranking. A man-portable tactical detector should use lithium because mass is decisive. A fixed ground cart can use NiMH because mass is not decisive, the cycle count is high, the charge profile is simple and the transport route is easier. A remote solar node may prefer LiFePO4 for cycle life, or NiMH for tolerance of trickle charge and low-temperature robustness. The correct choice depends on the weighting, not on a universal "best chemistry" claim.
NiMH cells are 1.2 V nominal, about 1.45 V at full charge and about 1.0 V at end of discharge under moderate load. A 20S string is 24 V nominal, 29 V full and 20 V empty; a 10S string is 12 V nominal, 14.5 V full and 10 V empty. The system's input window, not the nominal voltage, decides the cell count.
| System bus | NiMH cell count | Nominal | Full charge | End of discharge | Typical use |
|---|---|---|---|---|---|
| 12 V | 10S | 12.0 V | 14.5 V | 10.0 V | Small C2, test bench, remote node |
| 24 V | 20S | 24.0 V | 29.0 V | 20.0 V | Ground cart, vehicle buffer, training set |
| 28 V | 24S | 28.8 V | 34.8 V | 24.0 V | Military 28 V bus, legacy equipment |
| 48 V | 40S | 48.0 V | 58.0 V | 40.0 V | Fixed-site buffer, high-power test bench |
The full-charge voltage is the number that destroys converters. A 24 V bus that expects 24 V nominal may see 29 V from a fully charged 20S NiMH string; the DC-DC input must accept that, or the pack must be charged to a lower voltage. The end-of-discharge voltage is the number that causes brown-outs; the load must either accept 20 V or the low-voltage disconnect must trip before the load misbehaves.
Start with the average current, not the average power. For a 24 V bus, 293 W average is about 12.2 A. For a four-hour mission, the raw capacity is 48.8 Ah. Apply the derating stack to obtain the nameplate capacity:
Cnameplate = (Iavg × t) / (ktemp × kDoD × kEOL × krate × kwiring)
| Factor | Example value | Why it applies |
|---|---|---|
| Temperature | 0.80 | Capacity at −20 °C is lower than at 25 °C; use the coldest expected operating point |
| Depth of discharge | 0.90 | Do not plan to 100 % DoD if cycle life matters |
| End of life | 0.85 | Capacity at end of specified life, not beginning |
| Discharge rate | 0.95 | Higher rate reduces usable capacity |
| Wiring and connector loss | 0.97 | Voltage drop and contact resistance |
| Product | ≈ 0.60 | 48.8 Ah raw → about 81 Ah nameplate |
An 81 Ah nameplate requirement is large for a single 24 V NiMH pack; it may be better to use two 40 Ah packs in parallel, or to reduce the mission time, or to move the jammer to a separate pack. The arithmetic does not decide the architecture; it exposes the trade-off. A pack that looks adequate at 25 °C and 100 % DoD may deliver only 60 % of its nameplate in the real environment.
The pulse load is a separate design case. A 420 W jammer at 24 V draws about 17.5 A; a 1 kW pulse draws about 42 A. A 20S NiMH pack with 40 Ah cells may have an internal resistance of 20–40 mΩ including wiring, so a 42 A pulse produces a 0.8–1.7 V sag. That is tolerable on a 24 V bus if the amplifier's input range is 20–30 V; it is not tolerable if the amplifier cuts out at 22 V.
| Pulse current | Assumed pack resistance | Voltage sag | Remaining bus voltage from 24 V | Consequence |
|---|---|---|---|---|
| 20 A | 30 mΩ | 0.6 V | 23.4 V | Usually acceptable |
| 40 A | 30 mΩ | 1.2 V | 22.8 V | Check amplifier cut-off |
| 60 A | 30 mΩ | 1.8 V | 22.2 V | May trip a 22 V cut-off |
| 100 A | 30 mΩ | 3.0 V | 21.0 V | Requires shorter pulse or lower resistance |
The table is illustrative; the actual resistance depends on cell size, tab design, wiring and connector. The design response is not to add capacity but to reduce resistance: larger cells, shorter cables, heavier lugs, a connector with a lower contact resistance, and a capacitor bank at the amplifier input. A capacitor bank can supply the microsecond and millisecond pulse; the battery supplies the millisecond-to-second pulse; the converter supplies the average.
| Subsystem | Requirement | Why it matters |
|---|---|---|
| Charge method | Constant current 0.1–0.3 C, −ΔV termination, temperature cut-off | NiMH needs a proper termination; timer-only charging risks overcharge |
| Balance | String matching and periodic equalisation | Weak cells in a long string limit capacity and accelerate ageing |
| Low-voltage disconnect | Latching at 0.9–1.0 V per cell | Prevents cell reversal and permanent damage |
| Overcurrent protection | Fuse or breaker sized for pulse, not average | A 40 A continuous pack may see 100 A pulses |
| Reverse polarity | Series MOSFET or ideal diode | Field wiring errors are common |
| Temperature sensing | Thermistor per string, charger and load cut-off | Charge and discharge limits are temperature-dependent |
| Enclosure | IP54 for sheltered; IP65/67 for exposed | Dust, rain and wash-down are normal in field use |
| Mechanical | Vibration, shock and handling drop | MIL-STD-810H methods apply if the platform invokes them |
| Configuration | Electrical | Energy | Continuous / pulse | Typical use |
|---|---|---|---|---|
| Man-portable training pack | 10S 8 Ah, 12 V | 96 Wh | 8 A / 24 A | Training detector, test set, remote sensor |
| Ground-support cart | 20S 40 Ah, 24 V | 960 Wh | 30 A / 100 A | C2, chargers, test bench, short jammer bursts |
| Vehicle buffer | 20S 20 Ah, 24 V | 480 Wh | 20 A / 60 A | Engine-off C2 and ride-through |
| Fixed-site buffer | 40S 100 Ah, 48 V | 4.8 kWh | 50 A / 150 A | Generator start, UPS ride-through, test bench |

| Mistake | What it looks like | Consequence | Correct approach |
|---|---|---|---|
| Using RF output as DC input | "100 W jammer, so 100 W load" | Pack is undersized by a factor of three or more | Divide RF power by amplifier efficiency; add driver and cooling |
| Sizing from average only | "293 W average, so 300 W pack" | Pulse collapses the bus and resets the C2 | Check pulse current and voltage sag separately |
| Ignoring temperature | Using 25 °C capacity at −20 °C | Mission time falls by 20–40 % | Apply the cold derating factor and specify a heater if needed |
| Ignoring end of life | Using beginning-of-life capacity | Pack fails the mission before the warranty ends | Apply the EOL factor, typically 0.85 |
| Charging with a timer only | "8 h at 0.1 C is fine" | Overcharge, heat, shortened life | Use −ΔV and temperature cut-off; verify with a test |
| Testing cells, not the pack | Cell report only | Fuse, connector or enclosure fails in service | Qualify the complete pack configuration |
Divide the watt-hours by the nominal voltage. A 960 Wh pack at 24 V nominal is 40 Ah. Then apply the derating stack; the usable energy is lower than the nameplate, especially at low temperature and end of life.
Only if the system accepts the full-charge voltage of about 29 V and the end-of-discharge voltage of about 20 V. The nominal 24 V label is not the operating window. Check the DC-DC converter and the load's cut-off thresholds.
Usually not for the primary pack. A dismounted operator needs the highest energy density available, and lithium-ion delivers 150–250 Wh/kg versus 70–100 Wh/kg for NiMH. NiMH is better suited to training, ground support and legacy equipment where mass is less critical.
Overcharge without a proper termination, cell reversal from repeated deep discharge, high-temperature storage, and a weak cell in a long string. A charger with −ΔV and temperature cut-off, a latching low-voltage disconnect and string matching address most of these failure modes.
It depends on the cell, the pack resistance and the acceptable voltage sag. A well-built pack can supply 3–8 C for short pulses, but the datasheet must state the current, duration and sag. Do not assume that a 40 Ah pack can supply 100 A indefinitely.
IEC 61951-2:2017 + A1:2022, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride; IEC 62133-1:2017, Safety requirements for portable sealed secondary cells and batteries — Part 1: Nickel systems; IEC 60529, Degrees of protection provided by enclosures (IP Code); MIL-STD-810H, Environmental Engineering Considerations and Laboratory Tests; MIL-STD-461G, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment; UN Manual of Tests and Criteria, UN 3496; IATA Dangerous Goods Regulations, Packing Instruction A199. All numeric examples are illustrative planning calculations, not measurements.
Paper C — Testing and certifying those packs: IEC 61951-2 cell performance, IEC 62133-1 safety tests, IEC 60529 ingress, MIL-STD-810H environmental, MIL-STD-461G EMC, abuse testing and the UN 3496 transport route.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.