A counter-UAS support pack is qualified by evidence, not by a "military-grade" label. The evidence chain starts at the cell, runs through the pack, the enclosure, the charger and the platform, and ends at the transport document. Each link answers a different question: can the cell deliver the capacity after 500 cycles, can the pack survive an overcharge or a short circuit, can the enclosure keep water out, can the electronics pass EMC, and can the finished pack be shipped without a lithium test summary. This paper lays out that chain for sealed nickel-metal-hydride (NiMH) packs and explains which tests are mandatory, which are platform-specific, and which are marketing.
| Layer | Question answered | Typical evidence | Who owns it |
|---|---|---|---|
| Cell | Does the cell meet its capacity, rate and cycle-life claims? | IEC 61951-2 test report, cell datasheet, traceability | Cell manufacturer |
| Pack electrical | Does the string, wiring, fuse and connector survive the specified currents? | Design review, resistance measurement, pulse test | Pack integrator |
| Pack safety | Does the pack survive abuse and foreseeable misuse? | IEC 62133-1 test report, abuse test report | Pack integrator or test lab |
| Enclosure | Does the pack keep out dust and water? | IEC 60529 IP test report | Enclosure supplier and integrator |
| Environment | Does the pack survive temperature, humidity, salt, sand, vibration and shock? | MIL-STD-810H test report, or equivalent IEC 60068-2 tests | Test lab |
| EMC | Does the pack or charger interfere with the system, and is it immune to the system's emissions? | MIL-STD-461G or IEC 61000-4 test report | Test lab |
| Transport | Can the pack be shipped by road, sea and air? | UN 3496 classification, packing instruction, shipper declaration | Shipper and integrator |
The chain is not a checklist to be completed in any order. A cell that fails cycle life cannot be rescued by a good enclosure; a pack that fails IEC 62133-1 cannot be shipped on the basis of a good IP rating. The tests are independent evidence, and each has its own sample size and acceptance criterion.

IEC 61951-2 specifies performance tests for sealed NiMH cells and batteries. The tests that matter for a counter-UAS support pack are capacity at the specified rate, high-rate discharge, charge retention, endurance in cycles and, where applicable, low-temperature behaviour. The standard defines the test conditions; the manufacturer's datasheet should report the results at the same conditions, not at a different temperature or rate.
| Test | What it establishes | Typical condition | Design consequence |
|---|---|---|---|
| Rated capacity | Usable Ah at the specified rate | 0.2 C discharge to 1.0 V at 20 °C | Sets the nameplate; higher rates deliver less |
| High-rate discharge | Capacity at 1 C, 3 C or 5 C | Per standard or customer agreement | Sets the pulse capability and voltage sag |
| Charge retention | Self-discharge over a defined storage period | Typically 28 days at 20 °C | Sets the recharge interval for standby packs |
| Cycle life | Capacity after repeated charge/discharge | Defined C-rate, DoD and temperature | Sets the end-of-life derating factor |
| Low temperature | Capacity and voltage at −20 °C or the agreed temperature | Per customer agreement | Sets the cold derating factor and heater need |
A datasheet that reports only "40 Ah" without stating the discharge rate, temperature and cut-off voltage is not a specification. The same cell can be 40 Ah at 0.2 C and 36 Ah at 1 C; the difference matters when the pack is sized at the mission average.
IEC 62133-1 covers safety requirements for portable sealed nickel cells and batteries. It includes electrical, thermal and mechanical abuse tests, and it requires the pack to be evaluated as a system, not only as a collection of cells. The exact test list and sample size are defined by the standard and by the certification body; the table below is a planning summary, not a substitute for the standard.
| Test family | Example test | What it looks for | Typical acceptance |
|---|---|---|---|
| Electrical | External short circuit | Overheating, fire, leakage | No fire, no explosion, no excessive temperature |
| Electrical | Overcharge | Thermal runaway, venting | No fire, no explosion; functional check after |
| Electrical | Forced discharge | Cell reversal in a series string | No fire, no explosion; no leakage |
| Mechanical | Crush or impact | Internal short and thermal event | No fire, no explosion |
| Mechanical | Vibration and shock | Loose connections, cracked cells, welded joint failure | No disassembly, no leakage, capacity within tolerance |
| Thermal | Temperature cycling | Seal integrity, separator stability | No leakage, no fire, no explosion |
| Thermal | High-temperature storage | Venting, capacity loss | No leakage, no fire; capacity above the agreed floor |
The most common mistake is to test cells only and to assume the pack inherits the result. A pack adds welded tabs, a fuse, a connector, an enclosure and possibly a thermistor; each of those can fail a test that the cell passes. The safety report must identify the pack configuration, the cell type and the protection components.
| IP rating | Dust | Water | Typical counter-UAS support use | Test note |
|---|---|---|---|---|
| IP54 | Limited dust ingress | Splashing water | Sheltered ground cart, test bench | Good default for indoor or van-mounted equipment |
| IP65 | Dust tight | Water jets | Outdoor ground station, vehicle roof | Check connector and cable gland, not only the lid |
| IP67 | Dust tight | Immersion to 1 m for 30 min | Remote node, exposed mast, wash-down | Pressure and duration per the standard |
| IP68 | Dust tight | Continuous immersion beyond 1 m by agreement | Special marine or buried node | Requires a defined depth and duration |
An IP rating is a type test on a specimen, not a production guarantee. The production units must use the same gasket, the same connector, the same torque and the same cable gland as the tested specimen. A common failure is to qualify an IP67 enclosure with a sealed connector and then ship it with a vented pressure-relief plug that was not in the tested configuration.
MIL-STD-810H defines environmental test methods. The program manager selects the methods and procedures that match the platform's life cycle; the lab does not choose them. For a counter-UAS ground-support pack, the usual starting set is:
| Method | Title | Why it applies | Acceptance to define |
|---|---|---|---|
| 501.7 | High temperature | Vehicle cab, desert deployment, enclosure heating | No leakage, no deformation, capacity above floor |
| 502.7 | Low temperature | Cold storage, winter field use | No cracking, charge accepted after soak, capacity above floor |
| 503.7 | Temperature shock | Moving between heated cab and cold outside | No seal failure, no condensation-induced short |
| 507.6 | Humidity | Coastal and tropical sites | Insulation resistance above limit, no corrosion |
| 509.7 | Salt fog | Marine and coastal sites | No pitting of terminals, no leakage |
| 510.8 | Sand and dust | Desert and construction sites | No ingress, connector still mateable |
| 514.8 | Vibration | Vehicle transport and generator mounting | No loose cell, no cracked weld, no capacity loss |
| 516.8 | Shock | Handling drop and vehicle shock | No deformation, no internal short, functional check |
The method numbers and titles above are from MIL-STD-810H; the procedures and durations must be taken from the standard itself. A test report that says "MIL-STD-810H compliant" without naming the method, the procedure and the acceptance criterion is not evidence.
A counter-UAS site is an electromagnetically hostile place. The system's own jammer is the loudest emitter, but radar, datalink and switching converters also contribute. The battery pack is usually a victim rather than a source, but its charger and protection electronics can conduct and radiate.
| Requirement | What it covers | Typical test | Design response |
|---|---|---|---|
| CE102 | Conducted emissions, power leads | 10 kHz–10 MHz | Input filter, shielded cable, clean return path |
| RE102 | Radiated emissions | 10 kHz–18 GHz | Enclosure shielding, ferrite, twisted pairs |
| CS101 | Conducted susceptibility, power leads | 30 Hz–150 kHz | Filter and transient protection |
| RS103 | Radiated susceptibility | 14 kHz–40 GHz | Shielding, grounding, immunity of protection electronics |
| IEC 61000-4-2 | Electrostatic discharge | Contact and air discharge | TVS diodes, enclosure grounding, connector placement |
| IEC 61000-4-3 | Radiated immunity | 80 MHz–6 GHz | Filtering and shielding; test with the charger connected |
The test configuration matters. A pack that passes RE102 on a bench may fail when installed in a metal cart with a long unshielded charger cable. The EMC report should state the cable lengths, the enclosure, the charger and the load. If the pack is part of a larger system, the system-level EMC test is the authoritative one.
| Test | Purpose | Typical sample | Acceptance |
|---|---|---|---|
| Overcharge at 0.1 C and 0.5 C | Charger failure or stuck relay | 5 packs | No fire, no explosion, no leakage |
| External short at the terminals | Tool drop or cable fault | 5 packs | Fuse opens; no fire, no explosion |
| Over-discharge to 0.8 V per cell | Left-on load or failed LVD | 5 packs | No reversal, no leakage; capacity check before reuse |
| Drop from 1 m onto concrete | Handling | 3 packs | No cracking, no internal short, functional check |
| Vibration, 3 axes | Transport and vehicle | 3 packs | No loose part, no capacity loss above limit |
| Thermal cycling, −20 to +60 °C | Daily temperature swing | 3 packs | No leakage, no seal failure |
| Cycle life, 500 cycles | End-of-life capacity | 5 packs | Capacity ≥ 80 % of rated |
Sample sizes are planning values, not a quotation from a standard. The certification body and the customer's qualification plan define the actual sample size. The important point is that abuse tests are destructive: the samples tested are not the samples shipped. A production acceptance test should be non-destructive and should check capacity, insulation resistance, thermistor resistance and protection function.
Nickel-metal-hydride batteries are assigned UN 3496 in the UN Manual of Tests and Criteria. They are not lithium-ion cells or batteries, so UN 3480 and UN 3481 do not apply, and a UN 38.3 test summary is not required. The shipper still needs the correct packing instruction, package marking, quantity limits and, where applicable, a shipper's declaration.
| Mode | Applicable framework | Key document | Practical note |
|---|---|---|---|
| Road | ADR / national dangerous goods regulations | UN 3496 entry, packing instruction | Confirm whether the consignment is fully regulated or excepted |
| Sea | IMDG Code | UN 3496 entry, packing instruction | Container packing and marking |
| Air cargo | IATA DGR | Packing Instruction A199 | Quantity limits and state-of-charge rules may apply |
| Air passenger | IATA DGR / carrier rules | Carrier acceptance policy | Spare batteries are usually carry-on only; confirm with the carrier |
The transport classification is one of NiMH's practical advantages. A lithium pack of the same energy needs UN 38.3 evidence, lithium battery marks and often a more expensive logistics chain. A NiMH pack still needs paperwork, but the route is simpler and the test summary is not part of it. That advantage should be stated honestly: it is a logistics advantage, not a performance advantage.

No. UN 38.3 is the lithium battery test summary requirement. Nickel-metal-hydride batteries are assigned UN 3496, and the UN 38.3 summary is not part of that entry. The applicable packing instruction and quantity limits still apply.
No. IEC 62133-1 is the safety baseline for nickel cells and batteries. A military platform usually adds environmental, EMC, ingress and transport requirements. The exact set depends on the platform's qualification plan, not on a generic claim.
Only if the complete pack — enclosure, connector, cable gland, fuse holder and lid — was tested in that configuration. A commercial enclosure rating does not transfer automatically to a pack with a different connector or an added vent.
The standard and the certification body define the sample size; planning commonly uses five fresh samples per test lot, but the actual number depends on the test and the lab's procedure. Do not quote a sample size without confirming it with the lab.
Not the cell, but the integration: a fuse that is not rated for the pulse, a connector that is not sealed, a thermistor that is not potted, a charger that overcharges a weak string, or a pack that passes on the bench but fails EMC in the installed configuration. The fixes are mechanical and electrical, not chemical.
IEC 61951-2:2017 + A1:2022, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride; IEC 62133-1:2017, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications — Part 1: Nickel systems; IEC 60529, Degrees of protection provided by enclosures (IP Code); MIL-STD-810H, Environmental Engineering Considerations and Laboratory Tests; MIL-STD-461G, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment; IEC 61000-4 series, Electromagnetic compatibility (EMC) — Testing and measurement techniques; UN Manual of Tests and Criteria, UN 3496; IATA Dangerous Goods Regulations, Packing Instruction A199; IMDG Code; ADR. Test methods and sample sizes must be confirmed against the current editions and the customer's qualification plan.
This paper completes the counter-UAS support series. Paper A separated detection, jamming and C2 loads; Paper B turned those loads into a sizing procedure; Paper C turned the design into evidence. The common thread is honesty about chemistry: lithium owns the man-portable mission pack, and sealed NiMH earns its place in training, ground support, test benches, remote nodes and buffer roles.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.