A cordless power tool does not draw a steady current. It sleeps, then wakes when the trigger is pulled, accelerates a motor and a gearbox, cuts or drills into a load, and returns to sleep. The battery sees a low standby drain, a short inrush pulse, a working current that rises with torque, and occasional stall or jam currents that can be several times the normal load. The nameplate voltage and amp-hour rating describe only part of that duty. This paper separates the tool families, explains what the battery actually sees, and states where a sealed nickel-metal-hydride (NiMH) pack remains a defensible choice in a market now dominated by lithium-ion.
Power tools are often marketed by voltage, but the electrical load is set by the mechanism. A drill spends most of its time spinning freely and only briefly cutting; a grinder runs at high speed under a continuous abrasive load; a reciprocating saw has a mechanical stroke and a high instantaneous blade load; a blower is a continuous air load. The table below groups the common families by what the battery sees.
| Tool family | Typical examples | Electrical character | Dominant stress |
|---|---|---|---|
| Drilling and fastening | Drill-driver, impact driver, impact wrench, hammer drill | Short high-torque pulses; trigger inrush; idle between fasteners | Peak current, switch and connector heating, clutch slip |
| Sawing | Circular saw, reciprocating saw, jigsaw, chain saw | High working current under load; jam or kickback peaks | Stall current, blade bind, thermal pulse |
| Grinding and sanding | Angle grinder, random orbital sander, detail sander | Continuous medium-to-high current; speed droop under pressure | Continuous thermal load, dust ingress, vibration |
| Garden machinery | Hedge trimmer, string trimmer, leaf blower, lawn mower | Long continuous runs; high airflow or cutting load | Runtime, motor heating, outdoor temperature and moisture |
| Specialty tools | Rotary hammer, caulking gun, drain auger, concrete vibrator | Very high short pulses or slow high-torque output | Peak current, gearbox load, duty cycle |
The same 18 V pack may be sold across all five families. That does not mean the same cells or the same protection are appropriate. A compact drill pack optimised for weight will heat faster in a grinder; a garden pack optimised for runtime will be too heavy for overhead drilling. The pack must be matched to the tool family, not only to the connector.
Cordless tool voltage is a nominal cell count. NiMH cells are 1.2 V nominal, so 10 cells make a 12 V pack, 15 cells make an 18 V pack, 20 cells make a 24 V pack, and 30 cells make a 36 V pack. Lithium packs use a different cell count and a different nominal voltage per cell, which is why an "18 V" lithium pack and an "18 V" NiMH pack are not electrically interchangeable even when the connector looks similar.
| Nominal class | NiMH series count | Nominal voltage | Typical full-charge voltage | Typical cutoff | Common tools |
|---|---|---|---|---|---|
| 12 V | 10S | 12.0 V | ≈ 14.0–14.5 V | ≈ 10.0 V | Compact drills, drivers, detail sanders |
| 18 V | 15S | 18.0 V | ≈ 21.0–21.8 V | ≈ 15.0 V | Drills, impact drivers, saws, grinders, blowers |
| 24 V | 20S | 24.0 V | ≈ 28.0–29.0 V | ≈ 20.0 V | Heavy drills, rotary hammers, garden tools |
| 36 V | 30S | 36.0 V | ≈ 42.0–43.5 V | ≈ 30.0 V | Lawn mowers, chainsaws, heavy stationary tools |
The full-charge voltage is not a marketing number. A 15S NiMH pack taken to 1.45 V per cell reaches 21.75 V, and a charger that misses termination can push individual cells higher. The tool's switch, motor controller and any electronic speed control must be rated for the highest voltage the pack can deliver, not only the nominal 18 V. The cutoff must also be set with cell behaviour in mind: a 1.0 V per cell cutoff protects the weakest cell, while a 0.9 V per cell cutoff gains runtime at the cost of cycle life and risk of cell reversal.
A tool's current profile has four phases. The pack, fuse, switch and connector must survive all four. A cell datasheet that lists only a continuous 0.2 C capacity test does not describe any of them.
| Phase | Duration | Typical current | What it stresses | Design response |
|---|---|---|---|---|
| Standby / sleep | Hours to weeks | Microamps to a few milliamps | Self-discharge, electronics quiescent drain | Low-self-discharge cells; mechanical or electronic disconnect |
| Trigger inrush | Milliseconds | 2–5× running current | Switch contacts, connector, fuse, DC link | Pre-charge or soft-start; fuse with appropriate I²t; connector margin |
| Working load | Seconds to minutes | 5–30 A for an 18 V hand tool | Cell heating, voltage sag, motor efficiency | High-rate cells; matched internal resistance; thermal path |
| Stall or jam | Milliseconds to seconds | 50–150 A or more | Cell, switch, fuse, motor commutator | Electronic current limit; mechanical clutch; fuse; pack PTC |
The numbers are illustrative because tool and pack designs vary widely. The important point is the ratio: a tool that draws 10 A while drilling may draw 50 A at stall, and a pack that supplies 10 A without complaint may sag enough at 50 A to reset the tool's electronics or trip protection. The battery is not a reservoir with one current rating; it is a network of cells, welds, wires, connectors and protection devices, each with its own limit.

For a permanent-magnet DC motor, torque is approximately proportional to armature current, and back-EMF is approximately proportional to speed. At a given supply voltage, the current rises as the mechanical load slows the motor. A simplified relationship is:
T ≈ Kt × I and Vterminal ≈ VOCV − I × Rpack
Where Kt is the motor torque constant, VOCV is the pack open-circuit voltage, and Rpack is the pack resistance including cells, welds, wiring, connector and protection. The table below shows how a 15S pack with 90 mΩ total resistance behaves at different currents. The values are illustrative but the arithmetic is real.
| Pack current | Open-circuit voltage | Voltage sag at 90 mΩ | Terminal voltage | Approximate resistive loss |
|---|---|---|---|---|
| 5 A | 19.5 V | 0.45 V | 19.05 V | 2.3 W |
| 10 A | 19.5 V | 0.90 V | 18.60 V | 9.0 W |
| 20 A | 19.5 V | 1.80 V | 17.70 V | 36 W |
| 30 A | 19.5 V | 2.70 V | 16.80 V | 81 W |
| 50 A | 19.5 V | 4.50 V | 15.00 V | 225 W |
At 50 A the pack loses 225 W as heat inside cells, welds and connectors. That heat is the reason a high-rate pack cannot be judged only by its amp-hour label. A 3.0 Ah pack at 50 A is running at nearly 17 C; the cells may survive short pulses, but the pack's thermal path and the connector's contact resistance become the limiting components. The voltage sag also reduces the motor's speed and torque, which is why a "18 V" tool feels weaker on a partially discharged or cold pack.
The same arithmetic explains why a 2.0 Ah pack and a 4.0 Ah pack can have the same voltage but different sag. If the 4.0 Ah pack uses cells with lower internal resistance, it will hold voltage better under load. If it simply uses more capacity in the same cell format, it may have similar resistance per cell and no better peak performance. Amp-hour is energy; internal resistance is power capability. Both matter.
A tool's workday is not a continuous current test. A installer may drive twenty screws in a minute, each for two seconds, then set the tool down for a minute. A carpenter may run a circular saw for thirty seconds, then measure and reposition for two minutes. A landscaper may run a blower continuously for twenty minutes. The battery and motor heat according to the RMS current over the thermal time constant, not the simple average.
| Task | Work pulse | Rest between pulses | Approximate duty | Thermal character |
|---|---|---|---|---|
| Assembly driving | 1–3 s | 5–20 s | 5–30 % | Many short pulses; connector and switch heat |
| Drilling metal | 10–60 s | 10–60 s | 20–50 % | Medium continuous load; coolant and chip clearing |
| Circular sawing | 10–60 s | 10–120 s | 20–60 % | High current; blade bind possible |
| Angle grinding | 1–10 min | 1–5 min | 30–80 % | Continuous thermal load; dust ingress |
| Leaf blowing | 10–30 min | 0–5 min | 80–100 % | Continuous high airflow load; motor and pack heat |
A pack sized from average current will overheat in the grinder or blower case. A pack sized from the highest pulse will be unnecessarily heavy for the assembly case. The correct method is to calculate both the energy needed for the task and the RMS current over the thermal window, then choose a cell and pack that satisfy both. Paper B sets out that calculation.
The cordless tool market moved to lithium-ion for good reasons: more energy per kilogram, a flat discharge curve, accurate state of charge, fast charging and compact packs. A claim that NiMH is the best chemistry for a modern premium drill would be false. But the market is not monolithic. There are real segments where NiMH remains technically and commercially defensible.
| Application | Why NiMH fits | What to specify |
|---|---|---|
| Value-tier consumer tools | Low pack cost, mature chargers, simple electronics, tolerance of overcharge | 12 V or 18 V, 1.5–3.0 Ah, 10–20 A continuous, 40–60 A pulse |
| Legacy tool replacement | Original pack was NiMH; a drop-in replacement avoids tool and charger requalification | Match cell count, connector, thermistor curve and charge profile |
| Safety-sensitive or abusive use | Nickel chemistry is tolerant of over-discharge and mechanical abuse relative to lithium | IEC 62133-1, PTC, fuse, robust enclosure, 1.0 V/cell cutoff |
| Wide-temperature outdoor tools | NiMH can discharge below 0 °C and tolerate high ambient storage better than some lithium packs | −20 °C capacity data, 0–45 °C charge limit, thermal derating |
| Educational, rental and shared fleets | Low replacement cost, simple storage, no fuel gauge to calibrate | 18 V 2.0–3.0 Ah, 500+ cycles, mechanical keying, clear labelling |
| Test benches and charger buffers | Stable low-cost DC source for tool repair and production testing | 12/18/24 V, current limit, e-stop, thermistor, IP54 |
The table is a commercial map, not a claim of superiority. The value-tier segment competes on shelf price and replacement revenue. The legacy segment competes on fit and availability. The safety-sensitive segment competes on certification and abuse tolerance. A NiMH pack can win those segments without pretending to win the premium compact segment.

| Property | Sealed NiMH | Lithium-ion | What it means for a tool |
|---|---|---|---|
| Nominal cell voltage | 1.2 V | 3.6–3.7 V | NiMH needs more cells in series for the same pack voltage |
| Energy density | ≈ 50–80 Wh/kg pack | ≈ 120–200 Wh/kg pack | NiMH packs are heavier for the same energy |
| Discharge curve | Relatively flat, then a knee | Flat plateau, then a knee | Both are usable; NiMH gauge is less precise |
| High-rate capability | 10–20 C with high-rate cells | 20–40 C with power cells | Both can pulse; lithium holds voltage better |
| Overcharge tolerance | Good with correct termination and trickle | Requires strict protection | NiMH is more forgiving in low-cost chargers |
| Transport | UN 3496 sea; A199 air "not restricted" | UN 38.3, UN 3480/3481 | NiMH avoids lithium air-cargo paperwork |
The comparison is deliberately at pack level, because a cell comparison can mislead. A high-rate NiMH cell may match a lithium cell's pulse current in the short term, but the pack-level energy, mass and voltage sag still differ. The customer buys a pack, not a cell.
| Standard | Scope | Why it matters |
|---|---|---|
| IEC 61951-2:2017 + A1:2022 | Sealed NiMH cell performance and cycle life | Capacity, high-rate discharge, charge retention and endurance |
| IEC 62133-1:2017 / 2026 | Safety of portable sealed nickel cells and batteries | Abuse, thermal, mechanical and electrical safety |
| IEC 62841-1:2014 + AMD1:2025 | General safety of motor-operated tools; Annex K covers battery tools and packs | Tool-level electrical, thermal and mechanical safety |
| IEC 62841-2-1 / -2-2 / -2-3 / -2-5 / -2-11 | Particular requirements for drills, impact tools, grinders, saws | Tool-family-specific tests and markings |
| IEC 60335-2-29 | Safety of battery chargers | Charger thermal, electrical and abnormal-operation safety |
| CISPR 14-1 / EN 55014-1 and CISPR 14-2 / EN 55014-2 | EMC emission and immunity for household appliances and electric tools | Motor brush noise, charger conducted emissions, immunity |
| IEC 60529 | IP ingress protection | IP54 for general; IP65 for outdoor or dusty sites |
| UN 3496 / IATA A199 | NiMH transport by sea and air | Sea IMDG entry; air shipment "not restricted" with A199 conditions |
The standards list is not a claim that every pack needs every standard. A consumer 12 V drill pack may need IEC 62133-1, IEC 62841-1 Annex K and the relevant EMC standard. A garden tool pack may add IP65 and UV/moisture testing. A pack shipped by air needs the A199 packing conditions and the correct air waybill wording. Over-specification raises cost; under-specification blocks market access.
| Question | Why it changes the pack | Typical answer |
|---|---|---|
| Which tool family and model? | Sets peak current, duty cycle and connector | 18 V drill-driver, impact driver or grinder |
| What is the stall or jam current? | Sets fuse, PTC, switch and connector rating | 40–100 A for a hand tool; higher for garden tools |
| What runtime is required? | Sets cell capacity and pack mass | 30–60 min mixed use; 15–30 min continuous heavy use |
| What is the charge window? | Sets charger, termination and cell matching | 1–3 h; −ΔV plus temperature cutoff |
| What are the storage and use temperatures? | Sets capacity derating and charge limits | −20 to +50 °C outdoor; 0–40 °C indoor |
| Which certifications and markets? | Sets test plan and documentation | EU CE, UKCA, US, Japan, Korea or a subset |
A quote that starts with "18 V 3.0 Ah" is not a specification. The useful quote starts with the tool, the load, the duty, the connector, the charger and the market. The rest follows.
Cordless power tools are a high-rate, pulsed, thermally demanding application. The battery must supply inrush, working current and stall current without excessive sag, and it must survive repeated thermal cycles in a dirty, vibrating enclosure. Lithium-ion wins the premium compact segment on energy density and management features. Sealed NiMH remains a credible choice in value-tier tools, legacy replacement packs, safety-sensitive and wide-temperature applications, and test-bench or charger-buffer roles. The engineering task is not to argue chemistry in general; it is to match the cell, pack, protection and charger to the specific tool and duty.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.