2026-11-11
Paper B: selecting and sizing sealed NiMH packs for the support layer around spectrum analyzers and RF detectors. Match the application, choose the series cell count from 1.2 V, size capacity from the steady load and hours, and apply explicit depth-of-discharge, temperature and ageing derates. An overcharge-tolerant constant-current charger with PTC and fuse. The handheld battery stays lithium-ion; nickel belongs in docks, fixed nodes, AA/AAA devices and legacy testers.