Sizing a ground-support pack is an exercise in honest arithmetic. The aircraft's flight energy is irrelevant; what matters is the ground mission the pack actually serves — how many sorties, how many amp-hours at what voltage, how cold the flight line gets, and how long the pack must last before it is replaced. This paper sets out a repeatable sizing procedure for sealed nickel-metal-hydride (NiMH) packs used in unmanned-aircraft ground support, test, launch, recovery and training equipment. It uses worked examples rather than rules of thumb, and it states the derating stack explicitly so that the resulting number can be defended.
The load audit is a table, not a paragraph. For each load, record the voltage, the current in the worst realistic case, the duty cycle and the duration per sortie or per shift. Multiply current by time to get ampere-hours, and add a separate column for peak current that does not contribute to energy but does stress the pack.
| Load | Voltage | Average current | Duty / duration | Ah per shift | Peak current |
|---|---|---|---|---|---|
| Ground control station and display | 12 V | 4 A | Continuous, 4 h | 16 Ah at 12 V | 6 A |
| Datalink and recorder | 12 V | 1.5 A | Continuous, 4 h | 6 Ah at 12 V | 3 A |
| Launch controller | 24 V | 0.05 A standby | 8 h standby, 48 × 2 s pulses at 10 A | 0.4 Ah + 0.27 Ah | 10 A for 2 s |
| Recovery winch control | 24 V | 2 A | 10 min per recovery, 6 recoveries | 2 Ah | 25 A inrush |
| Battery test bench | 24 V | 3 A | 2 h per shift | 6 Ah | 5 A |
| Lighting and communications | 12 V | 1 A | 4 h | 4 Ah | 2 A |
The audit should distinguish loads that share a bus from loads that have their own supply. Two 12 V loads at 4 A and 1.5 A are 5.5 A on one bus, not 5.5 A on two. It should also record which loads are safety-critical: a ground station that loses power during landing is a different requirement from a work light that goes dark.
| Property | Sealed NiMH | Li-ion (NMC/LFP) | LiPo | Primary LiSO2 |
|---|---|---|---|---|
| Nominal cell voltage | 1.2 V | 3.6–3.7 V (LFP 3.2 V) | 3.7 V | 3.6 V |
| Gravimetric energy, cell level | 80–120 Wh/kg | 150–250 Wh/kg | 150–250 Wh/kg | 300–500 Wh/kg |
| Cycle life | 500–1,000 | 500–1,000 | 300–500 | Single use |
| Charge control | −ΔV, dT/dt or temperature ceiling; tolerant of simple chargers | CC/CV with per-cell monitoring and balancing | CC/CV with balance and protection | Not rechargeable |
| Cold capacity at −20 °C | ≈ 50–70 % of 25 °C capacity | ≈ 60–80 % | ≈ 60–75 % | Depends on cell design |
| Abuse tolerance | Good; no thermal-runaway cascade in the lithium sense | Requires protection and cell balancing | Requires protection and careful packaging | Not applicable |
| Transport | UN 3496; no UN 38.3 summary | UN 3480/3481; UN 38.3 summary | UN 3480/3481; UN 38.3 summary | UN 3090/3091 depending on configuration |
| Best fit in UAV support | GSE, test, launch, recovery, training | Flight packs, high-energy GSE | Flight packs | Single-mission devices |
The comparison is not a scorecard. NiMH loses on energy density and wins on charge simplicity, abuse tolerance and transport paperwork. For a ground cart that is charged from a vehicle alternator and stored in a container, those wins are worth more than the kilograms. For a flight pack, they are not.
| Bus | Cells in series | Nominal voltage | Typical charge voltage | End-of-discharge | Use |
|---|---|---|---|---|---|
| 6 V | 5 | 6.0 V | 7.0–7.5 V | 5.0 V | Legacy instruments, small test sets |
| 12 V | 10 | 12.0 V | 14.0–15.0 V | 10.0 V | Ground station, lights, hand-held controllers |
| 14.4 V | 12 | 14.4 V | 16.8–18.0 V | 12.0 V | 12S-equivalent training airframes |
| 24 V | 20 | 24.0 V | 28.0–30.0 V | 20.0 V | GSE cart, winch, launch compressor |
| 28.8 V | 24 | 28.8 V | 33.6–36.0 V | 24.0 V | 28 V avionics and military GSE |
Two practical rules follow. First, the pack voltage must stay inside the load's input window at end-of-discharge and at end-of-charge, not just at nominal. Second, the charger's output must match the cell count; a 20-cell pack charged by a 10-cell charger will be chronically undercharged, and a 10-cell pack charged by a 20-cell charger is a fire risk. The connector should be keyed so that the two cannot be interchanged.
Consider a cart that must run a ground control station, a datalink and a test bench for four hours between charges. The audit gives 3 A average at 24 V, with a 10 A peak when the winch starts. The required delivered energy is:
E = 24 V × 3 A × 4 h = 288 Wh Ah = 3 A × 4 h = 12 Ah
Apply the derating stack: 80 % depth of discharge, 90 % end-of-life aging, 90 % temperature at the lowest expected operating temperature, and 95 % wiring/rate loss. The combined factor is 0.8 × 0.9 × 0.9 × 0.95 = 0.616. The required nameplate capacity is 12 / 0.616 = 19.5 Ah. Select a 24 V 20 Ah pack (20 cells, 20 Ah), which gives 480 Wh nominal and about 296 Wh usable under the stated conditions. The 10 A peak is 0.5C, comfortably inside a 1C continuous rating; the 25 A winch inrush is 1.25C for less than a second, which the pack can supply if the connector and fuse are rated for it.
| Quantity | Value | Basis |
|---|---|---|
| Average load | 3 A at 24 V | Load audit |
| Mission duration | 4 h | Requirement |
| Delivered capacity | 12 Ah | 3 A × 4 h |
| Depth of discharge | 80 % | Cycle-life policy |
| End-of-life aging | 90 % | 2-year service target |
| Temperature | 90 % | −10 °C operating floor |
| Wiring and rate | 95 % | Cabling, connector, Peukert |
| Combined factor | 0.616 | Product of the four |
| Required nameplate | 19.5 Ah | 12 / 0.616 |
| Selected pack | 24 V 20 Ah, 20 cells | Next standard size |
A launch controller is a pulse load with a long standby. The audit is 50 mA standby for eight hours and 48 pulses of 10 A for two seconds. The energy per pulse is 10 A × 2 s = 5.56 mAh; 48 pulses are 0.27 Ah. Standby is 0.05 A × 8 h = 0.4 Ah. Total delivered is 0.67 Ah. Even with a 0.5 derating factor, a 2 Ah pack is sufficient on energy. The design driver is not energy but voltage sag and cold performance: a small 2 Ah pack at −20 °C may drop below the controller's brown-out threshold during a 10 A pulse. A 5 Ah pack, or a 2 Ah pack with a supercapacitor buffer, is the safer choice.
| Load element | Current | Duration | Delivered charge |
|---|---|---|---|
| Standby | 50 mA | 8 h | 0.40 Ah |
| Launch pulse | 10 A | 2 s × 48 | 0.27 Ah |
| Total | — | — | 0.67 Ah |
| Selected pack | — | — | 5 Ah, 20 cells, 10 A continuous / 30 A pulse |
| Factor | Typical multiplier | What it represents | How to verify |
|---|---|---|---|
| Depth of discharge | 0.80 | Keeping 20 % reserve for cycle life and unexpected loads | Cycle-life test at the intended DoD |
| Temperature | 0.70–0.95 | Capacity loss at cold; derating at high temperature for life | Discharge at the lowest and highest operating temperature |
| End-of-life aging | 0.85–0.90 | Capacity fade at the replacement point | Cycle-life data to 80 % capacity |
| Rate / Peukert | 0.90–0.95 | Capacity reduction at higher discharge rates | Discharge curve at the actual rate |
| Wiring and connector loss | 0.95 | Voltage drop and contact resistance | Measure at the pack terminals under load |
| Self-discharge / storage | 0.90–0.95 | Loss between charge and use | Storage test at the intended temperature |
The multipliers compound. A pack with a 0.8 DoD, 0.85 end-of-life, 0.9 cold and 0.95 wiring factor has a combined usable fraction of 0.58. That is why a 20 Ah nameplate often behaves like a 12 Ah pack in the field. The number is not a defect; it is the price of a pack that survives the mission and the warranty period.

| Method | Rate | Termination | Use / caution |
|---|---|---|---|
| Standard overnight | 0.1C | Timer 14–16 h plus temperature ceiling | Bench and depot; simplest, slowest |
| Fast charge | 0.3–1C | −ΔV of 5–10 mV per cell, or dT/dt, plus absolute temperature cut-off | Field charger; requires a matched charger and thermistor |
| Trickle / maintenance | 0.03–0.05C | Timer or temperature; never indefinite at high rate | Standby systems; overcharge heats and dries the cell |
| Opportunity charging | 0.2–0.5C | Partial charge, terminate on temperature or voltage | Vehicle or generator; accept partial state of charge |
Sealed NiMH cells do not tolerate indefinite trickle charge at a high rate. The charger should implement a primary termination (voltage drop or temperature rise), a backup timer, and a temperature ceiling. The pack should include a thermistor in thermal contact with the cells, and the charger should refuse to charge below 0 °C or above the specified maximum. A pack without a thermistor is a pack that depends on the operator to notice it getting hot.
| Element | Function | Typical specification | Failure mode if omitted |
|---|---|---|---|
| Thermistor | Charge and discharge temperature sensing | 10 kΩ NTC at 25 °C, mounted on cells | Overcharge or thermal runaway of the charger |
| Fuse | Short-circuit and reverse-polarity protection | Blade fuse or resettable PTC rated above pulse current | Connector weld, cable fire |
| Low-voltage cutoff | Prevent cell reversal | 1.0 V per cell under load, 1.1 V rest | Reversed cell, permanent capacity loss |
| Overcurrent / short protection | Limit external fault current | Electronic or fuse, 2–3× continuous rating | Welded contacts, melted insulation |
| Connector keying | Prevent wrong voltage or polarity | Different keying for 10-cell and 20-cell packs | Charger mismatch, immediate damage |
| Enclosure and vent | Ingress and pressure equalization | IP54–IP65, vented or sealed with a pressure-equalizing membrane | Condensation, corrosion, case distortion |
A 20-cell 24 V pack does not need per-cell balancing electronics in the way a lithium pack does, but it does need a pack-level cutoff and a fuse. The absence of a balancing BMS is a cost advantage only if the charger and the pack are designed as a pair; it is not a licence to omit protection.
| Requirement | Typical choice | Test / evidence |
|---|---|---|
| Enclosure | ABS or PC/ABS, flame-retardant, 2–3 mm wall | Drop, impact, UL 94 V-0 material data |
| Ingress | IP54 for sheltered GSE; IP65 for flight line; IP67 for exposed carts | IEC 60529 dust and water tests |
| Vibration | Cell immobilization, potting or structural ribs | MIL-STD-810H Method 514.8, tailored profile |
| Shock | Mounting bracket and crush space | MIL-STD-810H Method 516.8, handling drop |
| Temperature | Cell spacing, thermal path, charge inhibit below 0 °C | MIL-STD-810H Methods 501.7 / 502.7 or application profile |
| Altitude | Pressure-equalizing vent if the pack is air-shipped or stored at altitude | MIL-STD-810H Method 500.6, if applicable |
| Application | Configuration | Energy | Continuous / pulse | Charge | Notes |
|---|---|---|---|---|---|
| Ground-support cart | 20S 20 Ah (24 V) | 480 Wh nominal, ≈ 296 Wh usable | 20 A / 40 A 2 s | 0.2C, 6 h | IP54, 10 kΩ NTC, 30 A fuse, Anderson connector |
| Launch controller | 20S 5 Ah (24 V) | 120 Wh nominal, ≈ 74 Wh usable | 10 A / 30 A 2 s | 0.3C, 4 h | Cold-rated, keyed connector, low-voltage cutoff |
| Ground station backup | 10S 12 Ah (12 V) | 144 Wh nominal, ≈ 89 Wh usable | 6 A / 12 A | 0.2C, 6 h | Deep-cycle, 2-year service target, IP54 |
These are reference points, not catalogue items. The purpose is to show the arithmetic and the architecture, so that a customer's requirement can be mapped onto a configuration rather than guessed.

| Question | Why it matters | Typical answer |
|---|---|---|
| What is the average and peak current? | Sets cell size, tab, fuse and connector | 3–20 A average, 10–60 A pulse |
| How long must the pack run between charges? | Sets ampere-hours and charge logistics | 2–8 h, one shift |
| What is the lowest and highest temperature? | Sets usable capacity and charge inhibit | −20 to +55 °C |
| What is the intended service life? | Sets end-of-life derating and cycle target | 2–3 years, 300–500 cycles |
| Is the pack charged from mains, vehicle or generator? | Sets charger input and charge rate | 24 V vehicle or 230 V generator |
| What ingress and drop does it see? | Sets enclosure and mounting | IP54–IP65, 1 m drop |
| What transport mode and quantity? | Sets UN 3496 packing and documentation | Road and air, small quantities |
| Field | Example entry |
|---|---|
| Application and bus | UAV ground-support cart, 24 V DC |
| Chemistry | Sealed NiMH, 20 cells in series |
| Nominal energy / capacity | 480 Wh / 20 Ah |
| Continuous / pulse current | 20 A / 40 A for 2 s |
| Usable energy at −10 °C | ≥ 250 Wh |
| Charge method | 0.2C constant current, −ΔV and dT/dt, 0–40 °C |
| Protection | 30 A fuse, low-voltage cutoff at 1.0 V/cell, NTC, keyed connector |
| Ingress / mechanical | IP54, 1 m drop, MIL-STD-810H vibration tailored |
| Transport | UN 3496, state of charge 30–50 % |
| Documentation | Test report, UN 3496 statement, charging instructions, SDS |
Only if the load's voltage window, charge profile, connector and protection scheme are all compatible. A 20-cell NiMH pack charges to about 28–30 V and discharges to about 20 V; a 7S lithium pack charges to 29.4 V and discharges to about 21 V. The nominal voltages match, but the current limits, charge termination and transport rules do not.
Twenty cells in series at 1.2 V nominal each. The charge voltage is roughly 28–30 V and the end-of-discharge is roughly 20 V. A 28.8 V military bus uses 24 cells; a 12 V bus uses 10 cells.
Because the requirement is usually a service life, not a first-day performance. A pack that delivers 20 Ah when new but only 16 Ah at the two-year replacement point will fail the mission in its second year unless the initial capacity is selected with that fade in mind.
Not in the same sense as lithium. NiMH cells tolerate overcharge and can be equalized by a controlled overcharge, but the pack still needs a thermistor, a fuse, a low-voltage cutoff and a charger designed for the cell count. The absence of per-cell balancing electronics is not the same as the absence of protection.
Sealed cells recombine oxygen internally at moderate overcharge rates, which is why a controlled trickle is possible. At high rates or high temperature, pressure rises, electrolyte is lost and the cell dries out. That is why the charger needs a primary termination and a temperature ceiling, not just a timer.
No. UN 38.3 applies to lithium cells and batteries. Nickel-metal-hydride batteries do not require a UN 38.3 test summary. By air they are Not Restricted under IATA Special Provision A199 when short-circuit and unintentional activation are prevented; by sea they are UN 3496, Class 9, with special provisions 117 and 963. The pack should be shipped at 30–50 % state of charge and with the terminals protected against short circuit.
IEC 61951-2:2017+AMD1:2022, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary sealed cells and batteries for portable applications — Part 2: Nickel-metal hydride; IEC 62133-1:2017, Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications — Part 1: Nickel systems; IEC 60529:1989+AMD1:2013+AMD2:2013, Degrees of protection provided by enclosures (IP Code); UN Manual of Tests and Criteria, Part III, subsection 38.3 (lithium batteries) and the UN 3496 entry for nickel-metal-hydride batteries; ASTM F3005-22, Standard Specification for Batteries for Use in Small Unmanned Aircraft Systems (sUAS); MIL-STD-810H, Methods 500.6, 501.7, 502.7, 514.8 and 516.8; DJI Matrice 300 RTK and Matrice 350 RTK published battery and battery-station specifications. Worked examples are illustrative calculations, not test data.
Paper C — Testing and certifying sealed NiMH packs for UAV ground support: IEC 61951-2 cell tests, IEC 62133-1 pack tests, IEC 60529 ingress, MIL-STD-810H environmental sequences, MIL-STD-461G EMC and the UN 3496 transport route.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.