Nov.2026 20
Views: 120
Selecting and Sizing Sealed NiMH Packs for Unmanned Ground Vehicle Support: Mission Mix, Voltage Architecture, Derating, Hot-Swap and Charging
Introduction
Paper B: sizing sealed NiMH packs for UGV support. The mission mix table, 24 V versus 48 V architecture, cell configuration, the 0.62 derating stack, three worked examples (14 kg trainer, auxiliary sensor pack, two-bay depot charger), hot-swap design and fleet rotation.
Details

Selecting and sizing sealed NiMH packs for unmanned ground vehicle support

The first question is not "what capacity", it is "what does the robot do for the other twenty-three hours". A ground robot's pack is sized by the mix of moving, working, watching and charging, and that mix is different for a trainer, a legacy EOD platform and an auxiliary sensor bus. This paper turns the class and load frame from Paper A into a sizing procedure, works three examples at NiMH-appropriate scale, and sets out the hot-swap architecture that makes a small pack behave like a larger one.

Key facts at a glance

  • Build a mission mix table before a capacity number. The split between moving, working, watching and standby decides the energy, and it is usually dominated by the watching hours.
  • Size the connector from the peak, the pack from the average. Traction stall current and arm inrush set the connector and fuse; mission energy sets the cells.
  • Two small packs beat one large pack in the field. Hot-swap with a supervised bay turns a 2-hour pack into an 8-hour shift.
  • Derate NiMH by about 0.62 in a cold, end-of-life, high-rate duty. The four factors are multiplicative and should be listed, not hidden in a single margin.
  • Do not size a NiMH pack to a lithium endurance target. At one-third the energy for a comparable form factor, the honest answer is a shorter mission or a different chemistry.

The mission mix table

Phase Duration per shift Average power Energy Notes
Moving on flat ground h W Wh Measure on the actual surface
Climbing or stair work min W Wh Short and peaky; check voltage sag
Arm or manipulator work min W Wh Bursts; connector heating
Compute and perception h W Wh Often continuous for the whole shift
Radio and video link h W Wh Higher during transmission
Watch / standby h W Wh Sleep current and wake-on-event

Fill the table from a data-logging shunt on one representative shift, not from datasheet guesses. The total is the mission energy; the maximum column value is the peak that the connector, fuse and PCM must survive. If the watch phase is longer than the moving phase, expect the watch energy to dominate, and consider a separate small auxiliary pack rather than cycling the traction pack for a radio watch.

Voltage architecture: 24 V, 48 V and the dual-voltage legacy

Architecture Nominal Advantages Penalties Typical class
Single 24 V bus 24 V Matches legacy military and vehicle equipment; simple DC-DC Higher current for the same power; thicker harness Man-portable, small medium
Single 48 V bus 48 V Half the current; smaller connectors and FETs New DC-DC for 24 V payloads; isolation practice Medium and large
Dual-voltage pack 12/24 V or 24/48 V One pack serves two platforms; logistics simplification Contactors or configuration switching; operator error risk BB-390/U family
Dual-bay with ORing Bus-defined Hot-swap and redundancy Inrush control, bay supervisor, matching pack voltage Man-portable EOD

A dual-voltage NiMH pack is a genuine convenience: the BB-390/U offers 12 V 9.0 Ah or 24 V 4.5 Ah from the same block. The convenience has a cost, because the lower-voltage configuration delivers the same energy at twice the current, and the connector and wiring must be rated for that. A 12 V mode that is used only for a low-power sensor is fine; a 12 V mode used for traction is a different thermal problem.

Cell configuration for 24 V and 48 V packs

Configuration Nominal Full charge Cut-off Typical use
10S 12.0 V 14.5 V 9.0 V 12 V auxiliary, legacy 12 V mode
20S 24.0 V 29.0 V 18.0 V 24 V traction and payload
24S 28.8 V 34.8 V 21.6 V 28 V military bus approximation
40S 48.0 V 58.0 V 36.0 V 48 V traction

Two numbers need attention. A 20S pack reaches about 29 V at full charge, above a 24 V bus's usual 27.6 V float; the load must tolerate it or a DC-DC must be inserted. A 40S pack reaches about 58 V, which is above the 60 V safety threshold in many low-voltage definitions only by a small margin; insulation, creepage and connector rating become design issues rather than afterthoughts.

The derating stack for a NiMH traction pack

Factor Planning value Applies when Evidence to use
Temperature 0.85 at 0 °C; 0.70 at −20 °C Outdoor, unheated store Datasheet capacity-temperature curve
Rate 0.90 at 1C Traction peaks above 0.5C High-rate discharge curve
End of life 0.85 Fleet expected to reach 500 cycles 80 % capacity definition
Wiring 0.95 Harness longer than 0.5 m or connector resistance significant Measured voltage drop at rated current
Combined ≈ 0.62 Cold, high-rate, end-of-life duty Product of the four factors

The combined factor is deliberately conservative. A trainer that runs at 20 °C on a bench and is replaced at 300 cycles does not need 0.62; it might use 0.90. A field pack in a winter depot does. The point of listing the factors is that the reviewer can see which assumptions were made, and can challenge them individually.

Pack mass at equal usable energy

Usable energy target NiMH pack mass (est.) Lithium pack mass (est.) Mass penalty Practical consequence
100 Wh 1.5–2.0 kg 0.7–1.0 kg +0.8–1.0 kg Acceptable on a trainer
250 Wh 3.5–5.0 kg 1.6–2.4 kg +1.9–2.6 kg Noticeable on a man-portable platform
500 Wh 7.0–10.0 kg 3.2–4.8 kg +3.8–5.2 kg Changes the handling and the centre of gravity
1,000 Wh 14–20 kg 6.5–9.5 kg +7.5–10.5 kg Not viable for a man-portable robot

The estimates assume 60–120 Wh/kg for sealed NiMH packs and 150–250 Wh/kg for lithium packs, including enclosure and protection. They are planning figures, not quotations. The point is that the penalty grows linearly with energy, so the case for nickel weakens as the mission energy rises.

Worked example 1: a 14 kg trainer with a four-hour shift

Assume the trainer moves for 40 percent of a four-hour shift at 100 W average, and watches for 60 percent at 25 W. The mission energy is 0.4 × 4 × 100 + 0.6 × 4 × 25 = 160 + 60 = 220 Wh. At 24 V the raw capacity is 9.2 Ah. With the 0.62 stack the requirement is 14.8 Ah. Two 24 V 8 Ah packs give 384 Wh nominal and about 238 Wh derated, which covers the mission with a small margin and allows one bay to be swapped while the other carries the load. The mass penalty versus a 2590 lithium pair is real, and for a training platform it is acceptable; for a deployed platform it is not.

Worked example 2: an auxiliary sensor pack

A secondary sensor and radio draw 20 W for two hours from a 12 V bus. The energy is 40 Wh, the raw capacity is 3.3 Ah, and the derated requirement is about 5.4 Ah. A 10S 6 Ah pack is adequate. The important design point is isolation: the auxiliary pack should have its own DC-DC and its own return, so that a traction stall does not brown out the radio and so that a radio fault does not trip the traction protection.

Worked example 3: a two-bay depot charger

Two 24 V 8 Ah packs charged at 0.1C take 0.8 A each for 14–16 hours. The charger's output energy per pair is roughly 2 × 192 Wh × 1.2 / 0.8 ≈ 576 Wh, plus the charger's own quiescent draw. A depot with ten platforms needs twenty bays and a supply sized for the simultaneous worst case, or a sequenced charger that rotates bays. Sequencing is usually cheaper than upgrading the supply, and it also spreads the thermal load in the charging room.

Hot-swap architecture

Function Implementation Failure if omitted
Inrush limiting Pre-charge resistor or active hot-swap controller Connector arcing and welded contacts
Reverse current blocking ORing diodes or ideal-diode controller One pack charges the other; unequal discharge
Bay detection Presence switch or SMBus enumeration System assumes a pack is present and cuts off
Sequencing Supervisor prevents both bays empty under load Unexpected shutdown during a swap
Matching Same chemistry, voltage and state of charge Circulating current between packs
Connector rating Make/break current and cycle count specified Contact wear and intermittent faults

Hot-swap is a system property, not a connector property. The PackBot approach of two packs is instructive: the platform can run on one while the other is changed, and the supervisor knows which bay is active. A NiMH version of the same architecture works, provided the inrush controller is rated for the pack's short-circuit current and the connector is keyed to prevent a 12 V pack being inserted into a 24 V bay.

Connector and fuse worksheet

Parameter Formula or rule Example: 24 V 8 Ah pack, 40 A stall
Continuous current Average traction power / bus voltage 100 W / 24 V ≈ 4.2 A
Peak current Stall current per motor × number of motors 2 × 20 A = 40 A
Connector rating ≥ peak current, with make/break rating 50 A connector, keyed
Fuse Above peak for the stall duration, below harness ampacity 50 A slow-blow, 200 ms hold
Harness Voltage drop < 2 % at continuous current 2.5 mm² for 4.2 A over 1 m
PCM over-current trip Above fuse hold, below connector damage 60 A trip, 100 ms delay
Inrush limiter Energy absorbed during hot-swap Pre-charge resistor sized for 1,000 µF bus capacitance

Protection coordination is a chain: the PCM trips first for soft faults, the fuse clears hard faults, and the connector survives both. A pack that trips the PCM on every kerb has the wrong trip curve, not the wrong cells.

Charging, storage and fleet rotation

  • Charge at 0.1C where time allows. A 14–16 hour charge is gentle, needs only −ΔV and temperature termination, and suits a depot overnight cycle.
  • Do not fast-charge a cold pack. Bring it to above 0 °C first; charging a frozen NiMH pack causes permanent damage.
  • Store at about 40 percent state of charge for a season, and cycle every three months. A pack left fully charged on trickle in a hot room loses capacity faster than one stored cool.
  • Rotate the fleet. A first-in-first-out bay policy spreads cycles and prevents one pack from reaching end of life while its twins are barely used.
  • Log every pack. Serial number, cycle count, capacity check and bay history; without a log, a fleet cannot be sustained.
Mission mix and derating stack
Two-bay hot-swap architecture

Depot capacity check and acceptance

Check Frequency Method Acceptance
Open-circuit voltage Every issue and return DMM after 30 min rest Within 0.3 V of the expected SOC band
Capacity Every 50 cycles or quarterly 0.2C discharge to 1.0 V/cell ≥ 80 % of rated capacity
Charge termination Quarterly Observe −ΔV and temperature rise Terminates before 45 °C cell temperature
Insulation Quarterly 500 V insulation tester ≥ 10 MΩ
Connector and latch Every issue Visual and 10 mating cycles No damage; latch retains
Housing and seal Quarterly Visual, desiccant indicator No moisture; no cracks
Thermistor Quarterly Resistance at two temperatures Within tolerance of the curve

A depot that records these seven checks has a fleet it can sustain. A depot that records only "charged" has a fleet that fails one pack at a time, usually at the least convenient moment.

Frequently asked questions

How do I size a pack when the robot mostly watches?

Size from the watch energy, not the traction energy. A 25 W watch for 20 hours is 500 Wh, more than many traction missions. Consider a separate small auxiliary pack for the radio and compute, leaving the traction pack disconnected.

Can I use two different-capacity packs in the two bays?

Only if the supervisor prevents them from being paralleled and the platform can run on either alone. Paralleling a 4 Ah and an 8 Ah pack causes the smaller one to cycle deeper and fail early.

Is 48 V better than 24 V for a medium UGV?

For traction power above roughly 2 kW, 48 V reduces current and harness mass. For a man-portable platform, 24 V remains the practical choice because the whole ecosystem of chargers, radios and payloads is built around it.

How much does a NiMH pack weigh compared with lithium for the same energy?

Roughly 1.5–2.5 times as much, depending on cell grade and pack construction. That is why NiMH is a sustainment and auxiliary choice rather than an endurance-critical main pack.

What is the right depth of discharge for a training fleet?

Plan for about 60–70 percent to protect cycle life, and run a full discharge and recharge every three months to break up stratification and let the charger see a genuine end-of-charge signal.

Sources

PackBot 510 specifications (dual BB-2590, 4–8 h, 6 kg power pod); TALON specifications (lead-acid standard, 8.5 h, lithium option); THeMIS specifications (1,630 kg, diesel-electric, 15 h / 1.5 h); BB-2590/U and BB-390/U specifications; IEC 61951-2 charge methods; IEC 62133-1 safety tests; UN 3496 transport. Worked-example arithmetic uses the stated assumptions and the 0.62 combined derating factor; it is illustrative, not a product guarantee.

Next in this series

Paper C — Testing and certifying sealed NiMH packs for unmanned ground vehicles: shock and vibration to MIL-STD-810, ingress, EMC, abuse testing to IEC 62133-1 and the UN 3496 transport route. Paper A covers the UGV classes and load profiles behind this sizing work.

Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.

Lastest News
Unlock the power of lithium batteries for lasting performance in handheld vacuum cleaners. Weijiang Li-on Battery leads the charge in innovation.
READ MORE
A NiMH battery pack is a collection of individual NiMH batteries connected in series or parallel to create a higher voltage or capacity battery.
READ MORE
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Name*
Whatsapp/Phone
Email*
Message*
Professional battery factory, support OEM & ODM customization.
REQUEST MORE DETAILS
Please fill out the form below and click the button to request more information about
Company Name*
Email Address*
WhatsApp / Phone*
Message & Requirements*

Buyer fact sheet

Weijiang Power at a glance

Legal entityShenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power
Founded2010, 16 years of NiMH battery manufacturing
FactoryHuizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops
Capacity200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors
Product rangeNiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells
CertificationsCE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs
Markets60+ countries, focus on Europe and the United States
Order termsNo strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days
Medical NiMHMedical NiMH battery page

Quick answers for buyers

Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.

What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.

Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.

What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.

How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.

Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ

Language versions: Deutsch · Français · Español

Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.