A robot pack lives a harder life than a laptop pack and is certified less often. It is dropped off a tailgate, driven over kerbs, washed with a hose, left in a vehicle overnight at −10 °C, and then expected to accept a full charge in the morning. The certification question is not whether the cells are good; it is whether the assembly, the interconnect, the connector and the protection survive that sequence and still terminate charge correctly. This paper sets out the test programme for a sealed NiMH UGV support pack, the standards that apply at each level, and the acceptance criteria that make the result auditable.
| Level | Sample | Purpose | Standards | Owner |
|---|---|---|---|---|
| Cell qualification | Single cells, formed | Capacity, cycle life, abuse tolerance | IEC 61951-2, IEC 62133-1 | Cell manufacturer |
| Pack qualification | Assembled pack with PCM, fuse, thermistor, connector | Protection coordination, environmental survival | IEC 62133-1 pack tests, IEC 60068-2, IEC 60529 | Pack assembler |
| Platform integration | Pack installed in the robot | Hot-swap, charge bay, EMC, thermal | IEC 62368-1, MIL-STD-461, platform specification | Robot integrator |
| Logistics qualification | Packed for shipment | Transport classification and packaging | UN 3496, IATA DGR, IMDG | Shipper |
The levels answer different questions and should not be collapsed. A pack qualification report that does not name the charger, the harness length and the housing is incomplete for platform integration, and a platform test that used a laboratory charger does not qualify the production charger.
| Test | Standard | Typical level for a UGV pack | Duration | Failure to look for |
|---|---|---|---|---|
| Transport vibration | IEC 60068-2-6; MIL-STD-810 Method 514 | 10–55 Hz, 1 g sweep, three axes | 2 h per axis | Tab weld fatigue, screw loosening |
| Ground mobile vibration | MIL-STD-810 Method 514, category 8 | Application profile, often 5–500 Hz | Per mission profile | Busbar cracking, connector fretting |
| Handling shock | IEC 60068-2-27; MIL-STD-810 Method 516 | 15 g, 11 ms, three axes | 3 shocks per axis | Cell displacement, fuse integrity |
| Drop | IEC 62133-1; MIL-STD-810 Method 516 | 1 m onto concrete, pack level | 3 drops, different faces | Cracked housing, PCM damage |
| Stack drop | Platform-specific | Tailgate height, 0.6–0.9 m | Per handling procedure | Connector latch failure |
Vibration testing should be run with the pack mounted as it is in the robot, including the bracket and the harness. A pack tested loose on a shaker table is a different mechanical system from one clamped in a chassis with a 1 m harness. The harness is a vibration contributor, not an accessory: it can whip, fatigue the connector and radiate the very noise that the EMC test is trying to measure.
| Declared rating | Test | Typical UGV exposure | Design consequence |
|---|---|---|---|
| IP54 | Dust protected, splashing water | Indoor trainer, light rain | Gasketed housing, drip path |
| IP65 | Dust tight, water jets | Deck and field wash-down | Sealed connector, jet-rated seal |
| IP67 | Immersion 1 m, 30 min | Flooded basement, ford | Pressure-rated connector and seal |
| IP68 (declared) | Continuous immersion at declared depth | Submersible variant only | Pressure test at depth with safety factor |
Wash-down is the most common real exposure and the least often tested. A hose at 4–6 bar directed at the connector for a few minutes is harsher than the IPX5 jet in the standard, because the operator aims at the seal. Test the assembly with the connector mated and with it unmated, and inspect the inside of the housing for moisture after each test. A desiccant indicator inside the housing is a cheap and honest witness.
| Condition | Typical requirement | Test method | Consequence if violated |
|---|---|---|---|
| Storage, cold | −20 °C | IEC 60068-2-1 cold soak | Capacity loss; case brittleness |
| Operation, cold | −20 °C discharge | Cold chamber, rated load | Voltage sag and early cut-off |
| Storage, hot | +55 °C | IEC 60068-2-2 dry heat | Electrolyte loss, seal creep |
| Charge, cold limit | No charge below 0 °C | Chamber with charger | Gassing, permanent damage |
| Charge, hot limit | Charge derated above 40 °C; stop at 45 °C cell | Thermocouple on hottest cell | Thermal runaway risk |
| Thermal cycling | −20 to +55 °C, 10 cycles | IEC 60068-2-14 | Condensation, seal fatigue |
The cold-charge prohibition is absolute for NiMH. A charger that starts charging as soon as a pack is inserted, without a pack thermistor above 0 °C, will eventually charge a frozen pack left in a vehicle overnight. The fix is simple: the charger reads the thermistor and waits; the cost of the wait is a delayed shift, the cost of the violation is a failed pack.
| Test | Standard | Source of interference | What to check |
|---|---|---|---|
| Conducted emissions | MIL-STD-461 CE102; EN 55011 | Motor PWM and DC-DC | Noise on the battery leads, 10 kHz–10 MHz |
| Radiated emissions | MIL-STD-461 RE102; EN 55011 | Switching converters, long harness | Radiated field at 1 m |
| Conducted susceptibility | MIL-STD-461 CS114/CS115/CS116 | Radio transients, cable coupling | PCM reset or false trip |
| Radiated susceptibility | MIL-STD-461 RS103; IEC 61000-4-3 | Radios on the platform | Protection false trigger, display upset |
| ESD | IEC 61000-4-2; MIL-STD-461 CS118 | Operator contact with connector | PCM latch-up, connector damage |
| Surge / burst | IEC 61000-4-4 / -4-5 | Relay and contactor switching | Fuse nuisance operation |
A passive NiMH pack does not generate emissions, but the pack is part of the return path and the pack's harness is an antenna. Test with the robot's own motors running, not with a resistive load. The most common finding is a PCM that resets during a motor stall because the supply dipped and the reset threshold was set too close to the cut-off voltage.
| Test | Condition | Acceptance | Pack-specific concern |
|---|---|---|---|
| External short | Short at the connector, 20 °C | No fire, no explosion; fuse operates | Fuse rating versus harness rating |
| Overcharge | 0.1C for 24 h with protection bypassed on one sample | No fire, no explosion; venting permitted within limits | Thermistor placement and charge termination |
| Forced discharge | One cell reversed in a string | No fire, no explosion | Cell-group voltage monitoring |
| Impact | Drop 1 m, steel surface | No fire, no explosion | Housing crush and cell compression |
| Thermal abuse | +70 °C soak | No fire, no explosion | Seal and vent path |
| Crush | 13 kN or application-specific | No fire, no explosion | Vehicle rollover scenario |
Abuse tests are performed on samples that are deliberately unprotected in one function, to prove the chemistry's tolerance. They are not a substitute for the protection design; they are evidence that the design has a margin when a protection function fails. A pack that passes abuse only because the PCM works has demonstrated the PCM, not the cells.
| Mode | Rule | Classification | Documentation |
|---|---|---|---|
| Air | IATA DGR | UN 3496, Class 9 | Packing instruction; no UN 38.3 summary |
| Sea | IMDG | UN 3496, Class 9 | Dangerous goods declaration where required |
| Road | ADR | UN 3496, Class 9 | Transport document |
| Rail | RID | UN 3496, Class 9 | Transport document |
Two errors recur in UGV logistics. The first is attaching a lithium UN 38.3 summary to a nickel pack because the freight forwarder asked for "the battery test summary"; the correct response is a UN 3496 classification and the nickel packing instruction. The second is shipping a prototype pack as "equipment" without a classification at all. Both are paperwork failures that can ground a shipment, and neither is a cell-quality problem.
| Sample | Pre-test | Tests | Acceptance |
|---|---|---|---|
| Pack, 3 pcs | Capacity check, 0.2C | Vibration, shock, drop | No structural damage; capacity ≥ 95 % of pre-test |
| Pack, 3 pcs | Insulation and seal check | IP54/65/67 per declaration, wash-down | No moisture inside; insulation ≥ 10 MΩ |
| Pack, 3 pcs | Thermistor calibration | Cold, hot, thermal cycling | Charge inhibits below 0 °C; termination above 45 °C |
| Pack, 3 pcs | Protection verification | Overcharge, short, forced discharge | Protection operates; no fire or explosion |
| Pack, 3 pcs | Baseline emissions | CE102/RE102 with robot motors running | Within limit; no PCM reset |
| System, 1 set | Hot-swap procedure | Swap under load, both bays | No shutdown; no arcing; supervisor correct |
| System, 1 set | Production charger | Full charge, termination, trickle | Terminates on −ΔV and temperature; no overcharge |
Acceptance criteria must be numeric where possible. "No structural damage" should be expanded to a defined inspection: no cracked housing, no loose busbar, no displaced cell, connector latch intact, fuse continuity, thermistor resistance within tolerance. A test report that says "passed" without the inspection list is not evidence.


No. UN 38.3 is the lithium battery test summary. Nickel-metal-hydride packs ship under UN 3496 with the applicable packing instruction and transport document.
Method 501 for temperature, 507 for humidity, 510 for sand and dust, 514 for vibration, 516 for shock, and 509 for salt fog if the platform is exposed to a marine environment. The method is a framework; the levels come from the platform's own environmental specification.
Pack-level tests can be run on a bench, but EMC, hot-swap and charge-bay tests need the platform and the production charger. A bench-only programme leaves the highest-risk integration failures untested.
No structural damage, no loose interconnect, capacity at least 95 percent of the pre-test value, insulation resistance at least 10 MΩ, and a functional check of the protection circuits. Visual inspection alone is not sufficient.
Three packs per environmental test group is a practical minimum for a first article. Abuse tests are destructive and typically use three samples per test. A pilot lot of ten packs gives enough data to detect lot-to-lot variation without excessive cost.
No. A deeply discharged NiMH pack can reverse a weak cell and, on recharge, heat locally. The low-voltage disconnect should be latching, and a pack that has been below 0.9 V per cell for weeks should be capacity-checked before reuse, not simply recharged.
IEC 61951-2 for sealed NiMH performance; IEC 62133-1 for nickel-system safety; IEC 60529 for IP codes; IEC 60068-2-1/-2/-6/-14/-27/-30/-52 for environmental testing; MIL-STD-810G/810H Methods 501, 507, 509, 510, 514, 516; MIL-STD-461 for CE102, RE102, CS114/115/116, RS103 and CS118; IEC 61000-4-2/-3/-4/-5 for EMC immunity; UN 3496, IATA DGR, IMDG, ADR and RID for transport. Test levels quoted are typical planning values; the platform or contract specification governs.
Paper A covers UGV classes and load profiles; Paper B covers selection, sizing, derating and hot-swap architecture. This paper closes the C12 set on sealed NiMH in unmanned ground vehicle support.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Medical NiMH battery page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?