This is Paper A of the C09 note on UAV and drone ground control station backup power, and it settles the first question an OEM battery engineer has to answer before any cell or pack is sized: how does a ground control station actually work, and what kind of electrical load does it present? A ground control station is the ground node of an unmanned aircraft system, running mission planning, flight control, payload management, full-motion video and telemetry, and a loss of power can interrupt the command link, lose mission data and force a control handover. The modern answer is a rugged computer and human-machine interface fed by a power distribution unit, an external source such as an AC adapter, PoE, a vehicle bus or a generator, and a backup battery with a seamless switchover path that holds the station through a sudden outage or a vehicle-start voltage collapse. This paper maps the GCS classes, the STANAG 4586 architecture, the power and data-link design and the switchover mechanism, states the mixed standby-plus-peak load the battery sees, and states honestly where sealed nickel-metal hydride is the correct chemistry and where the station's own lithium chemistry is. The selection and sizing work follows in later papers. Every figure that is not a published specification is labelled illustrative, and the binding values for a real project remain the device manual and the agreed pack drawing.
Key fact 1. The starting point is a continuity problem rather than an energy-density problem. A ground control station must keep control of the aircraft and the data link alive when the external source fails, the vehicle engine cranks the bus down or a generator or PoE supply drops, so the design is built around ride-through and a clean shutdown rather than a long off-grid run.
Key fact 2. GCS hardware spans five deployment classes: handheld and soldier-portable controllers, portable tri-fold and case stations, vehicle-mounted stations, fixed shelter and building cockpits, and remote PoE relay nodes. Each class changes the external source, the battery size and the environmental envelope, but all share a rugged computer, a human-machine interface, a data-link terminal and a power distribution unit.
Key fact 3. The control architecture is defined by STANAG 4586, which structures the ground station into the human-computer interface, a core control system, a data-link interface and a vehicle-specific module, and defines the levels of interoperability that let one station control different aircraft and payloads.
Key fact 4. The power architecture converts one higher-voltage bus or battery into several rails through efficient DC-DC converters, and a power-MUX or redundant input switches to the backup source with a minimal voltage dip. Published remote-node data show a typical draw in the teens of watts peaking near sixty-five watts with heating, and a small internal backup pack covering only tens of minutes of ride-through.
Key fact 5. The honest chemistry split is clear. The station's own internal batteries are lithium-ion and lithium-polymer, which is not a place to claim nickel-metal hydride. Sealed NiMH is the defensible choice one layer out, in rechargeable operator training packs, garrison and multi-bay chargers, AA/AAA-compatible accessories and legacy gear, and in dock and solar-gateway buffers, where simple charging, abuse tolerance and not-restricted shipping matter more than the highest internal energy density.
The first principle is to understand why the backup exists at all. A ground control station is the point from which an operator commands the aircraft, receives its telemetry and watches its payload video, and that link has to stay coherent through the mission. If the external source disappears while the station is live, the computer can lose unsaved mission data, the data-link radio can drop and the aircraft has to be handed over or brought home safely. The backup is therefore sized first to bridge the interruption and support an orderly shutdown or handover, and only secondarily to extend independent operation, which is a different requirement from the aircraft's own long-endurance battery.
Several real events drive the requirement. On a vehicle-mounted station the engine start collapses the nominal 28-volt bus toward cranking voltage, and load changes and alternator behaviour push surges and spikes back onto the same bus. A fixed shelter depends on mains and a generator that can fail or switch, and a remote PoE node sits on a single outdoor cable that can be cut or lose its injector. In each case the station has to survive the disturbance and keep running, which is the job of the input conditioning, the power distribution unit and the backup battery rather than of the main computer.
| GCS class | How it is powered | Typical form |
|---|---|---|
| Handheld / soldier-portable | Internal battery, external DC when available | Integrated controller or rugged tablet |
| Portable case / tri-fold | AC adapter plus internal Li-ion pack | Multi-screen carry-on case with joysticks |
| Vehicle-mounted | 28 V vehicle bus, quiet generator, backup | Rack or console inside the vehicle |
| Fixed / shelter / building | Mains through a UPS, generator backup | Multi-screen dual-seat cockpit |
| Remote PoE node / relay | PoE injector plus small internal backup | Sealed elevated radio node |
The functional architecture of a military ground station is defined by STANAG 4586, the NATO standard for the interfaces of UAV control systems, which sets out what has to be implemented to reach a given level of interoperability. Its functional elements are the air vehicle, a vehicle-specific module, a data-link interface, a core UAV control system, a command and control interface and a human-computer interface. Industry material groups these into four layers: the human-computer interface the operator sees and touches, the core control system that holds the authoritative mission state and arbitrates which station holds control, the data-link interface, and the vehicle-specific module that adapts the common core to a particular aircraft.
The standard covers both command and control and payload communications, and the levels of interoperability describe how much authority a station holds; a remote video terminal, for example, reaches the level at which an operator can bidirectionally control the payload, which sits below full flight control. Related STANAGs cover the interoperable data link and the digital sensor and video formats, including the video standard used with metadata overlays. This matters for power design because every one of these layers is a load: the display and controls, the processing core, the radio and the vehicle-specific interface all draw from the same distribution unit, and a switchover has to hold all of them at once.
A ground station usually starts from one higher-voltage battery or bus and derives the rails each subsystem needs through several DC-DC converters rather than running every device at the source voltage. Modern switching converters with synchronous rectification routinely exceed ninety-two percent efficiency and can approach ninety-six percent, and a wide input range lets the converter ride the natural voltage sag of a discharging battery. This matters because a linear regulator would turn the voltage difference into heat inside a sealed enclosure, while a switching converter keeps the rails stable and the thermal load manageable.
Published power distribution hardware makes the architecture concrete. A rugged 900-watt unit provides four independent, configurable outputs across the avionics, servo and payload rails, accepts two battery inputs over a wide voltage range for several lithium chemistries and an umbilical input, and gives the main outputs full redundancy by combining two independent supplies each able to carry the full load, with serial and bus monitoring of voltage, current and temperature. The redundant input and the per-rail conversion are the mechanism that lets one station survive a failed source or a shorted rail without losing the whole system.

The data-link terminal is often the most demanding and most safety-critical load in the station, carrying command and control, telemetry and video between the ground and the aircraft. Line-of-sight command links run from VHF into the C-band, and the C-band is the most common for larger systems because the low-gigahertz frequencies are less affected by severe weather; small aircraft use UHF, while the L-band around 1.4 gigahertz supports long beyond-visual-range links with good penetration under licence. Short-range systems use the unlicensed 2.4 and 5.8 gigahertz bands, which are crowded and attenuate quickly, and beyond-line-of-sight operation reaches up through Ku-band satellite links.
Ground stations pair the radio with a directional antenna and an antenna tracker that uses the aircraft position from telemetry to point a high-gain antenna in azimuth and elevation, which adds motor and servo loads on top of the radio itself. The radio and the tracker have to stay powered through a switchover, because a dropped link is exactly the failure the backup is meant to prevent. This is why the backup is specified against the station's actual transmitting and tracking load rather than against the computer alone.
| Published anchor | Power character | Backup character |
|---|---|---|
| Remote PoE node (published specs) | Typical 17.1 W, low-power 7 W, peak 65 W with heating | 23.4 Wh LiPo, about 30-45 min ride-through |
| Handheld controller (published specs) | Integrated screen and radio, internal pack | About 4-5 h runtime, runs on external DC |
| Portable case station (published specs) | 120 W adapter, internal 14.8 V Li-ion | Up to about 6 h internal runtime |
| Tactical mission power node (published) | Up to 1.5 kW managed output, smart batteries | Auto external-to-battery switch, hot-swap cells |

When it is reduced to its electrical shape, a ground station presents a mixed load rather than a flat one: long idle and monitoring at low power, broken by peaks when the radio transmits, the antenna tracker moves, the computer runs a processing burst or the heater comes on. The backup design does not remove these peaks; it lets the backup pack deliver them while holding every rail at its correct voltage. Reference designs use a power multiplexer with redundant inputs that detects the main rail falling past a threshold and switches to the backup with a minimal output dip, then switches back when the main source returns, with current limiting, overvoltage and reverse-current protection.
Larger tactical nodes extend the same logic. Published mission power systems hold several smart batteries and automatically transition between external and battery power, allowing batteries to be hot-swapped without interrupting the load, and rugged battery boxes built from standard military smart batteries can act as a UPS, a power supply or a standalone unit. The pattern is consistent across classes: the internal battery is a ride-through and shutdown asset, not a long off-grid store, and published remote-node figures of only tens of minutes on the internal pack confirm that role. Any current or runtime that is not a published specification is labelled illustrative.
The published data establish what the station's internal batteries actually are. Handheld controllers and rugged laptops use internal lithium-ion and lithium-polymer packs, often dual hot-swappable, and remote nodes use a small lithium-polymer backup; vehicle and fixed stations historically also use sealed lead-acid or the vehicle bus with a generator. The honest statement is that lithium is the chemistry inside the modern station because its high energy density keeps the load light and the runtime usable, and sealed nickel-metal hydride is not claimed in that space.
The genuine nickel role begins one layer out, and it includes a real training logic. Rechargeable nickel packs can be cycled repeatedly at low unit cost and without hazardous-goods restrictions, so they replace expensive lithium packs and primaries that would otherwise be consumed while operators train on the station and its peripherals; they also fit garrison and multi-bay chargers, AA/AAA-compatible accessories and legacy devices, and dock and solar-gateway buffers, because a sealed nickel cell holds a flat 1.2-volt platform, tolerates overcharge and rough handling, contains no cadmium and no free liquid, and ships not-restricted. The trade-off is lower energy density, so a nickel pack needs more cells and is heavier than an equivalent lithium pack, which is exactly why it belongs in training, support and fixed equipment rather than inside the station.
The environmental boundary is stated plainly. Station electronics and their lithium packs are built for wide temperature windows, with remote nodes and rugged computers operating across roughly minus forty to plus fifty-five degrees when paired with the right supply and heating. Sealed nickel-metal hydride is less prone to permanent cold damage than lithium and retains a usable share of capacity, but low temperature still reduces the capacity available and charging has to be controlled, with a practical rechargeable nickel field limit around minus twenty degrees. No claim is made that a sealed nickel cell outperforms the station's lithium battery on energy density or weight; its honest strength is repeated use, simple recharge and not-restricted handling in equipment that comes back.
The scope is stated rather than stretched. Sealed NiMH is not offered as the station's internal battery, where lithium is the correct choice, and it is not offered as a replacement for a military smart battery or a hot-swappable laptop pack. The genuine applications are rechargeable operator training packs that replace consumed lithium, garrison and multi-bay chargers and docks, AA/AAA-compatible accessories and legacy gear, and buffer packs in power-management docks and solar gateways. All of these return and recharge, which is the condition under which the nickel chemistry pays off. Within that scope the mixed standby-and-peak load is well matched to a robust sealed nickel cell.
To keep the command link and the computer alive when the external source fails. Vehicle starts collapse the 28-volt bus, generators and PoE injectors can drop and mains can fail, so the backup bridges the interruption and supports an orderly handover or shutdown rather than serving as a long off-grid battery.
It is the NATO standard for the interfaces of UAV control systems, defining the human-computer interface, the core control system, the data-link interface and the vehicle-specific module and the levels of interoperability. Each layer is an electrical load the power distribution unit has to hold through a switchover.
It takes one higher-voltage bus or battery and derives several rails through efficient DC-DC converters, with redundant inputs and per-rail monitoring. Published units give the main outputs full redundancy from two independent supplies and accept multiple battery and umbilical inputs.
A power multiplexer detects the main rail falling past a threshold and switches to the backup with a minimal voltage dip, then back when the main source returns. Larger nodes add automatic external-to-battery transition and battery hot-swap without interrupting the load.
Lithium-ion and lithium-polymer, including hot-swappable laptop and controller packs and small remote-node backups. Sealed nickel-metal hydride is not claimed inside the station; its honest place is in training packs, garrison chargers and docks, AA/AAA accessories and legacy and buffer equipment.
The GCS taxonomy and architecture draw on published STANAG 4586 references, manufacturer data and military program material covering the station classes, the power distribution unit and DC-DC rails, the data-link bands and antenna tracking, and the seamless switchover and hot-swap mechanism. The power figures, including the remote-node typical draw in the teens of watts and peak near sixty-five watts and the tens-of-minutes internal ride-through, are published values rather than measurements of a named product, and the load levels in the figures are illustrative. Nickel cells and packs are qualified to IEC 61951-2 and IEC 62133-1 and ship under UN 3496 with the IATA A199 not-restricted air path, while the station's lithium batteries follow their own lithium transport rules. No statistics have been invented.
Weijiang Power supplies sealed NiMH cells and assembled NiMH packs for rechargeable operator training batteries, garrison and multi-bay chargers and docks, AA/AAA-compatible accessories and legacy gear and buffer packs in power-management and solar-gateway equipment, built to the device geometry at the required voltage with PTC and resettable-fuse protection. The cells are qualified to IEC 61951-2 and IEC 62133-1 and the packs ship under UN 3496 with the not-restricted air path under IATA A199. We do not present NiMH as a station's internal battery, and we do not manufacture lithium-ion cells; lithium work is pack assembly only. Send us your station class and bus voltages, measured idle, transmit, tracking and heater currents, expected ride-through and shutdown time, temperature range and charging arrangement, and we will work through the chemistry match, cell count and pack design and support the evidence for your evaluation. See the Weijiang NiMH product range for standard pack formats, or contact our OEM team with the device specification and load profile.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, UN38.3, IEC 62133; 16 patents |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Custom NiMH packs for non-implantable medical devices: patient monitors, infusion pumps, diagnostic carts and backup systems; IEC 62133, IEC 61951-2 and MSDS. Medical NiMH page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, UN38.3 and IEC 62133, with 16 patents.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.