Underwater sensing is not radar with a different antenna. The ocean carries acoustic energy at roughly 1/2000 the speed of light, attenuates it frequency-dependently, and fills the channel with shipping noise, reverberation and biological sound. The result is a family of sensors whose electrical load profiles differ far more from each other than radar sites differ from radio sites: a sonobuoy that must run for eight hours on a seawater-activated primary battery, a dipping sonar that transmits through a 2,500 ft cable from a helicopter, a hull-mounted array drawing tens of kilowatts, and an acoustic modem that sleeps at 2.5 mW between messages. This paper sets out those classes, the arithmetic that connects source level to electrical power, the duty cycles that decide thermal and battery sizing, and the narrow support layer in which a sealed nickel-metal-hydride (NiMH) pack is an honest choice.
The word "sonar" covers devices that share a transducer but almost nothing else. The table below separates them by platform, frequency, typical source level and the part of the power budget that dominates.
| Class | Platform and typical band | Transmit character | Dominant electrical load |
|---|---|---|---|
| Hull-mounted active sonar | Surface ship or submarine; 2–30 kHz typical, lower for long range | Pulsed, kilowatts to tens of kilowatts, duty around 1 % | Transmitter average power, beamformer and signal processing, ship hotel load |
| Dipping sonar | Helicopter; medium frequency, multi-frequency in ALFS | Pulsed through a 2,500 ft cable, high peak | Transmitter, reeling machine, aircraft electrical bus |
| Towed array / passive sonar | Ship or submarine; very low frequency | Receive only | Hydrophone arrays, towed-cable telemetry, processing |
| Sonobuoy | Air-dropped A-size buoy; passive DIFAR or active | 1 W VHF telemetry; acoustic receive or ping | Primary battery energy over 0.5–8 h |
| Multibeam / side-scan / sub-bottom | Survey vessel or AUV; 12 kHz multibeam, 3.5 kHz sub-bottom, 100–500 kHz side-scan | Short pulses, fan-shaped or fan-steered | Transmitter average power and motion compensation |
| Acoustic modem / USBL | Fixed node, AUV, diver, surface station; 9–65 kHz | Short packets, tens of watts for milliseconds | Wake-up receiver, sleep current, transmit bursts |
The distinction matters because a procurement specification written for one class is meaningless for another. A sonobuoy specification is an energy-per-8-hours specification. A hull sonar specification is an average-power and cooling specification. An acoustic modem specification is a sleep-current specification with a transmit burst stacked on top. Treating them as a single "sonar battery" category is the first mistake in a support-equipment brief.
Sonar engineers quote source level in decibels relative to one microparascal at one metre. The conversion to electrical power is the first place where a battery conversation can go wrong.
SL ≈ 170.8 + 10 log10(Pacoustic) + DI Pacoustic = η × Pelectrical
Here DI is the directivity index of the projector and η is its electro-acoustic efficiency. The 170.8 dB term is the reference level of a one-watt omnidirectional source in water. Two consequences follow immediately. First, a directional array buys source level without buying electrical power: 20 dB of directivity is worth a hundredfold power reduction for the same on-axis level. Second, efficiency is a real multiplier: a projector that converts 30 percent of its electrical input into acoustic energy dissipates more than twice as much heat as it radiates, and that heat has to leave the transducer and the cabinet.
| Example | Frequency | Published source level | What the number implies |
|---|---|---|---|
| Scientific split-beam echosounder | 38 kHz / 120 kHz | 2 kW at 38 kHz, 500 W at 120 kHz (transmit power) | Short pulses; average power is a small fraction of the setting |
| Multibeam echosounder | 10.5–13 kHz | 242 dB re 1 µPa rms maximum | Fan-shaped transmit, 2–15 ms pulses, eight sectors per ping |
| Sub-bottom profiler | 3.5 kHz | 10 kW nominal, 3 kW radiated, 222 dB | Long 64 ms pulse once per second; low duty but high peak |
| Scientific scanning sonar | 20–30 kHz, 256 elements | 209.5–215.4 dB | 4–72 ms pulses, 360° beamformed coverage |
| Small high-frequency sonar | 60/153 kHz or 85/215 kHz | 1 kW output | 0.2–20 ms pulses; short range, high resolution |
Notice that the published "output power" of a sonar is usually the electrical input to the transmitter, not the acoustic power in the water, and almost never the average power drawn from the platform. For a battery or UPS calculation, the only relevant number is the average electrical draw over a defined mission, including the processing and display chain. That is why a 10 kW-rated profiler can be fed from a modest generator, while a 1 kW-rated sonar with a 90 percent duty cycle cannot.
For a pulse of duration τ repeated every pulse-repetition period T, the duty cycle is D = τ / T, and average power is Pavg = Ppeak × D. The same arithmetic used for radar applies here, but the range of D is wider.
| Operating mode | Pulse length | Repetition | Duty cycle | Design consequence |
|---|---|---|---|---|
| Conventional pulsed active sonar | 0.5 s | 20 s | 2.5 % | Energy storage in capacitors; average thermal load modest |
| High-duty-cycle sonar (experiment) | 18 s | 20 s | 90 % | Average power, cooling and continuous transmitter rating dominate |
| Multibeam echosounder | 2–15 ms | 5–20 s | < 0.3 % | Very high peak, very low average; capacitor bank and thermal transient |
| Sub-bottom profiler | 64 ms | 1 s | 6.4 % | Long pulse; average power is a real fraction of nominal |
| Acoustic modem packet | tens of ms | minutes to hours | < 0.1 % | Sleep current, not transmit power, sets the energy budget |
| Sonobuoy telemetry | continuous FM carrier | continuous | ≈ 100 % | 1 W RF continuously for the selected life; primary energy dominates |
The HDC case is worth dwelling on because it breaks the intuition that sonar is always a pulse problem. A 2013–2015 experiment in 20 m water compared a 0.5 s pulse at 2.5 percent duty with an 18 s pulse at 90 percent duty, chosen so that both carried equal energy. The low-duty pulse had to be 15.6 dB stronger to carry the same energy; the high-duty source could run at 182 dB instead of 197.6 dB. In battery terms, the high-duty mode trades peak power for average power and cooling. A pack that can deliver a 2 kW pulse for half a second may still overheat if asked to deliver 500 W continuously.
A sonar transducer is rarely the largest load on the platform, and almost never the largest energy consumer over a mission. The table below is an illustrative partition for three platform types; it is a planning aid, not a measurement.
| Platform | Transmit / acoustic | Processing and display | Motion, reeling, cooling | Hotel / auxiliary |
|---|---|---|---|---|
| Surface ship, hull sonar | 10–30 % | 15–25 % | 10–20 % (cooling, stabilization) | Remainder: lighting, HVAC, other systems |
| Helicopter, dipping sonar | 20–40 % during transmit | 10–20 % | Reeling machine: high short-term hydraulic or electric demand | Avionics and flight loads |
| AUV, side-scan or multibeam payload | 20–50 % during survey lines | 15–30 % | Propulsion 30–60 % | Navigation, communications, hotel |
| Moored acoustic node | Transmit bursts < 5 % of time | Duty-cycled | None | Sleep and listen current dominate |
This partition explains a recurring field complaint: a support battery sized from the sonar's nameplate power ends up oversized, while one sized from the average electronics load ends up unable to supply the transmit burst. Both numbers are needed, and they belong to different parts of the power train.
| Support load | Typical power | Duty | Why it matters to the pack |
|---|---|---|---|
| Handling winch or cable reel | 0.5–3 kW | Minutes per deployment | Often the largest single load on a small boat; may share the battery bus |
| Slip ring and cable compensation | 50–300 W | Continuous while deployed | Adds a constant drain during the whole survey |
| Cooling fan and cabinet ventilation | 20–100 W | Continuous in warm weather | Easy to forget; runs even when the sonar is idle |
| Console, display and recorder | 100–400 W | Continuous | Defines the baseline hotel load |
| Workshop test instruments | 50–200 W | Per test session | The load a bench NiMH pack usually serves |
| Lighting and communications | 20–150 W | Night and transit | Small but continuous; dominates long standby periods |
Support loads are the reason a "sonar battery" is rarely sized by the sonar alone. On a small survey boat the winch, the display and the ventilation can exceed the acoustic transmit power averaged over a day. The pack specification should list them explicitly, with a measured or nameplate figure for each, and should state which of them share the battery bus and which have their own supply.
| Platform | Prime source | Storage / backup | Voltage domain | What a NiMH pack can and cannot touch |
|---|---|---|---|---|
| Surface ship | Diesel or gas-turbine generators | Ship UPS for console and processing; no battery on the transmitter | 440/230 V AC, 24 V DC controls | Portable test sets and handheld instruments only |
| Helicopter | Aircraft generator | Aircraft battery and emergency bus | 115 V AC 400 Hz, 28 V DC | Ground support and test equipment, not the sonar |
| Sonobuoy | Seawater-activated or LiSO2 primary | None; single mission | Internal, typically 12–28 V | No rechargeable pack in the buoy |
| AUV / ROV | Pressure-tolerant Li-ion or Li-polymer | Single main pack, sometimes a second pack | 24–355 V DC | No NiMH traction pack; possible auxiliary/support only if the vehicle designer permits |
| Moored node / modem | Primary lithium or rechargeable pack | Rechargeable where serviceable | 12–24 V DC | Yes, when the modem vendor offers a NiMH internal option |
| Deck test set | Mains or 28 V DC | Internal rechargeable for carry-between-positions | 12–24 V DC | Yes: a well-defined, defensible NiMH application |
Sonobuoy. The AN/SSQ-53H DIFAR is a 9.5 kg A-size buoy with a LiSO2 power source, a 1 W minimum VHF transmitter on one of 97 channels between 136.0 and 173.5 MHz, and a selectable operating life of 0.5, 1, 2, 4 or 8 hours. The earlier SSQ-53D(3) uses a seawater-activated battery, weighs 7.1 kg, and scuttles after eight hours regardless of the selected life. Shelf life is five years in the sealed container; unpacked storage life is 90 days. These are single-mission devices: the energy source is sized once, activated once, and discarded with the buoy.
Dipping sonar. The AN/AQS-22 ALFS is the US Navy's airborne low-frequency dipping sonar, integrated with the MH-60R. It deploys a transducer assembly on 2,500 ft of coaxial cable, with a receive array of twelve hydrophone stave arms, and it is described as the only deployed dipping active sonar with multi-frequency operation. The dry end — transmitter/receiver, acoustic processor, reeling-machine controls — is powered from the aircraft. The wet end is a passive-and-active transducer at the end of a cable. There is no battery in the water path; the energy comes from the helicopter.
AUV. The Fraunhofer IBMT pressure-balanced deep-sea battery is a useful anchor: 4.1 kWh, 159 Ah at 25.9 V nominal (21–29.4 V), 50 A discharge, 50 kg, rated to 6,000 m, with up to 63 modules in one vehicle. Kraken SeaPower covers 5.0–22.8 kWh per module at 45–355 V, 6,000 m, with 145 Wh/kg and 260 Wh/l claimed for its pressure-neutral packaging. The General Dynamics Bluefin 1.5 kWh pack is 30 V, 48 Ah, 6,000 m, rechargeable in six hours or less. Every one of these is lithium chemistry; none is NiMH.
| Device | Energy / capacity | Voltage | Depth | Chemistry |
|---|---|---|---|---|
| AN/SSQ-53H sonobuoy | 8 h mission, 1 W RF | Internal | Floating, hydrophone at depth | LiSO2 primary |
| AN/SSQ-53D(3) sonobuoy | 8 h maximum | Internal | 30–300 m selectable | Seawater-activated primary |
| Fraunhofer deep-sea module | 4.1 kWh, 159 Ah | 21–29.4 V | 6,000 m | Lithium-polymer, pressure-balanced |
| Kraken SeaPower module | 5.0–22.8 kWh | 45–355 V | 6,000 m | Li-ion NMC, pressure-neutral |
| Bluefin 1.5 kWh pack | 1.5 kWh, 48 Ah | 30 V nominal | 6,000 m | Lithium-polymer, oil-compensated |
| EvoLogics PRO USBL modem | Up to 342.8 Wh internal | 12/24 V DC | Model-dependent | Rechargeable NiMH or Li-ion (vendor option) |
Acoustic modems are the exception that proves the rule. EvoLogics publishes, for its PRO USBL 42/65, a stand-by consumption of 2.5 mW, a listen mode of 5–285 mW, a receive mode of 1.4 W, and a maximum output of 55 W, with a maximum source level of 188 dB. The same datasheet lists the internal battery option as rechargeable NiMH or Li-ion, up to 342.8 Wh. This is not an inference or a marketing claim; it is a vendor-documented configuration.
Why does NiMH survive here? Because the modem's energy problem is dominated by sleep and listen, not by transmit. A pack that sits at tens of milliwatts for weeks, accepts a full charge without a balancing BMS, and tolerates being left on trickle in a sealed housing is a better fit than a lithium pack that needs cell balancing and a protection board for a load it never sees. The same logic applies to a moored sensor node that wakes on an acoustic or timed interrupt, sends a short packet, and goes back to sleep.
There is a second, less glamorous slot: the deck. A sonar test set, a hydrophone preamplifier checker, a buoy test bench, a handling-team radio, a portable USBL beacon — these are 12–24 V, tens of watts, intermittent, and often charged from a vehicle or a 19-inch rack. A sealed NiMH pack with a simple constant-current charger and a thermistor is adequate, transportable as not-restricted nickel chemistry, and repairable in a way that a potted lithium pack is not.

| Question | Why the answer changes the pack | Typical answer to expect |
|---|---|---|
| What is the transmit power, pulse length and repetition rate? | Sets peak current, duty cycle and thermal load | 1–10 kW peak, 0.2–20 ms, 0.1–1 Hz for survey sonar |
| What is the prime source voltage and architecture? | Sets cell count and whether a DC-DC is needed | 24 V or 48 V DC plant; 12 V for small sets |
| Where is the battery physically located? | Sets ingress, shock, vibration and temperature requirements | Dry console, deck locker or pressure housing |
| Is the pack charged in place or swapped? | Sets hot-swap, connector and charger architecture | Swapped at shift change on small boats |
| What depth and pressure is the housing rated for? | Distinguishes IP rating from a depth rating | Deck equipment: IP54–IP65; subsea: pressure-rated |
| How is the pack transported and stored? | Sets UN 3496 documentation and state of charge | Road and sea; stored at 30–50 % SOC |
These six answers, recorded in writing, prevent most of the mismatch that appears later as a "battery problem". They also make clear which party owns the pressure boundary and which owns the charge termination.
Write the requirement around the duty cycle of the support task, not around the sonar's nameplate. A deck test set that runs two hours per shift, at 12 V and 2 A, needs 4 Ah per shift before derating. A moored modem that sleeps at 2.5 mW and transmits for a few seconds per hour needs an energy budget dominated by its sleep current. A buoy test bench that is used intermittently needs cycle life and shelf life, not energy density. None of those requirements is served by quoting the sonar's peak power.
The next paper turns these principles into a sizing procedure: load audit, chemistry comparison, cell count, derating stack, charge termination and protection. The third paper covers the test and certification route, including the pressure and ingress tests that a "waterproof" claim usually omits.

No. In-service A-size DIFAR sonobuoys use LiSO2 or seawater-activated primary batteries, selected for a single mission of 0.5 to 8 hours and a five-year sealed shelf life. A rechargeable pack would add self-discharge, charge-control electronics and mass to a device that is deliberately expended.
Not in the transmit path. The AN/AQS-22 dry end is powered from the helicopter and the wet end is a cable-deployed transducer. NiMH appears in ground test equipment and support instruments, not in the sonar itself.
For an omnidirectional projector with 50 percent efficiency, about 1 kW of electrical input produces roughly 197 dB; 200 dB needs about 2 kW. Directivity reduces the electrical requirement for the same on-axis level, which is why array design matters more than raw amplifier power.
Because the average power, not the peak, sets the thermal load. A 90 percent duty cycle at 500 W average dissipates heat continuously, while a 2.5 percent duty cycle at 2 kW peak has long cooling intervals between pulses. The energy may be equal; the temperature rise is not.
Yes, in a dry, pressure-resistant housing on a deck or in a surface buoy, provided the pack is vented or designed for the enclosure's pressure and temperature cycle. It should not be confused with a pressure-balanced, oil-filled AUV pack, which is a different mechanical and chemical architecture.
Nickel-metal-hydride batteries travel under UN 3496, not the lithium entries UN 3480 or UN 3481, and no UN 38.3 test summary is required. The actual packing instruction and quantity limits depend on the configuration and the mode; the shipper should confirm them for each shipment.
Ultra Maritime, AN/SSQ-53H DIFAR sonobuoy datasheet (LiSO2, 1 W RF, 0.5–8 h, 9.5 kg); Ultra Maritime, AN/SSQ-53D(3) passive directional sonobuoy datasheet (seawater-activated battery, 7.1 kg, 8 h); DTIC ADA030105, 8-hour AN/SSQ-53 seawater battery development; Raytheon and US Navy descriptions of the AN/AQS-22 ALFS (2,500 ft cable, twelve hydrophone staves, multi-frequency); DTIC AD1024342, high-duty-cycle versus pulsed active sonar experiment (0.5 s/20 s versus 18 s/20 s); Furuno CH-600 sonar specification (1 kW output, 0.2–20 ms pulse); Neptune Sonar T160 projector datasheet (2.8 kHz, 750 Vrms at 10 percent duty); Fraunhofer IBMT deep-sea battery datasheet (4.1 kWh, 159 Ah, 6,000 m); Kraken SeaPower technical book (5.0–22.8 kWh modules, 45–355 V, 145 Wh/kg); General Dynamics Bluefin 1.5 kWh subsea battery datasheet (30 V, 48 Ah, 6,000 m); EvoLogics PRO USBL 42/65 datasheet (2.5 mW standby, 55 W maximum output, NiMH or Li-ion internal battery up to 342.8 Wh). Values marked illustrative in the text are planning figures, not measurements.
Paper B — Selecting and sizing sealed NiMH packs for sonar and underwater support equipment: load audit, chemistry comparison, cell configuration, derating stack, charge termination and protection. Paper C — Testing and certifying those packs: IEC 61951-2, IEC 62133-1, IP and pressure testing, environmental sequences, EMC and the UN 3496 route.
Weijiang Power — sealed NiMH cells and packs for industrial support equipment.
OEM and custom configurations, with honest chemistry boundaries. Visit our product range or browse the full technical series.
Buyer fact sheet
| Legal entity | Shenzhen Weijiang Battery Co., Ltd., trading as Weijiang Power |
| Founded | 2010, 16 years of NiMH battery manufacturing |
| Factory | Huizhou Shenzhou Super Power Technology Co., Ltd., Zhongkai High-tech Zone, Huizhou, Guangdong; 12,000 m2, 4 workshops |
| Capacity | 200,000 NiMH cells per day; 200+ staff including 11-20 R&D engineers and 10 QC inspectors |
| Product range | NiMH cells A, AA, AAA, SC, C, D, 9V, F, Sub-C, 4/5AA, 2/3A; custom NiMH packs; chargers; button and alkaline cells |
| Certifications | CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001:2015, ISO 14001, IATF 16949, IEC 62321, MSDS, UL, IEC 62133; 16 patents; UN38.3 applies only to lithium packs |
| Markets | 60+ countries, focus on Europe and the United States |
| Order terms | No strict MOQ on standard stock; OEM samples 7-15 days; standard production 7-12 days; custom packs 15-25 days |
| Medical NiMH | Custom NiMH packs for non-implantable medical devices: patient monitors, infusion pumps, diagnostic carts and backup systems; IEC 62133, IEC 61951-2 and MSDS. Medical NiMH page |
Who is Weijiang Power?
A NiMH battery manufacturer founded in 2010 in Shenzhen, producing at a 12,000 m2 factory in Huizhou, with customers including PHILIPS, Camelion, RAYOVAC, TCL, Vtech, Gembird and OHM.
What can Weijiang Power supply?
Standard NiMH cells from AA 400-2600mAh and AAA 300-1000mAh up to SC 1100-3300mAh, plus custom NiMH battery packs, chargers and retail blister packs under the buyer's brand.
Which certificates are available for EU and US buyers?
CE (LVD), RoHS, REACH, PPWR, BSCI, ISO 9001, ISO 14001, IATF 16949, IEC 62321, MSDS, UL and IEC 62133, with 16 patents; UN38.3 applies only to lithium packs.
What is the minimum order and lead time?
Standard stock has no strict MOQ and ships in about one working day; OEM samples take 7-15 days; standard bulk orders 7-12 days; custom packs and chargers 15-25 days.
How do I get a sample or a quote?
Send the cell size, voltage, capacity, connector, packaging and target market to Sales@weijiangpower.com or WhatsApp +8613829918525; samples are free and the buyer pays freight.
Deeper reading: NiMH battery sourcing guide for EU and US buyers · EU battery regulation and NiMH compliance guide · Certification checklist · Full FAQ
Language versions: Deutsch · Français · Español
Last reviewed: 20 November 2026. Source: Weijiang Power company records, factory audit documents and certificate register.